Water temperature (Tmax). ..............35 °C
Hose connection ................ 1" (30,3 mm)
Switch-on pressure (preconfigured)
p(on) .....................
0,15 MPa (1,5 bar)
Cut-off pressure (preconfigured)
p(off) ..........................
0,3 MPa (3 bar)
Protection class ..................................... I
Protection type ................................. IPX4
Sound pressure level
(L
pA
) .............. 61,6 dB (A); K
pA
= 3,2 dB
Sound power level (L
WA
)
measured ..... 81,6 dB (A); K
WA
= 3,2 dB
guaranteed .......................... 91 dB (A)
Safety information
This section describes the basic safety
rules when working with the domestic wa-
ter system.
Symbols used in the
instruction manual
Hazard symbol with
information on the pre-
vention of personal in-
jury or property dama-
ge
There is a danger
of burns!
Hazard symbol with informa-
tion on damage prevention
Remove the mains plug
Advisory symbol with infor-
mation on how to best use
the device
Graphical symbols
on the device
Attention! Read the in-
struction manual.
Not suitable for pure
sandwater.
Attention: Avoid dry running
of the pump! Danger of over-
heating!
Attention! If the mains cable
is damaged or cut through,
immediately remove the plug
from the mains socket.
G1“
IN
Water inlet
G1“
OUT
Water outlet
The sound power level L
WA
is
indicated in dB
Electrical devices must not be
disposed of with domestic wa-
ste.
General safety instructions
Using the device:
Caution: This is how to avoid
accidents and injuries:
• This device can be used by chil-
dren aged 8 years and up as
well as individuals with reduced
physical, sensory or mental
abilities or a lack of experience
and knowledge if they are su-
pervised or have been instructed