PDBNP 14 B1
GB
│
IE
│
19
■
Use
♦
The appliance is ready for use as soon as the
pneumatic air flow has been established.
♦
Screw the pin collector onto the thread for
the pin collector at the back of the machine.
♦
Determine the suitable rivet size on the basis of
the workpieces used.
♦
Use a suitable tool to drill a hole into the work-
pieces in the spot where the rivet will be
located. Make sure the diameter of the hole
corresponds to the determined rivet size.
CAUTION!
►
Suitable safety precautions must be taken
depending on the size and nature of the
workpieces. Use suitable clamping devices
to prevent the workpieces from slipping.
►
In the event of an interruption to the air
supply, release the trigger immediately.
►
Before switching on the machine, make sure
the machine tool is firmly placed on the
surface to be processed.
♦
Check if the diameter of the attached mouth-
piece matches the mandrel diameter of the
determined rivet size.
♦
If it does not, unscrew the front connector
using the assembly spanner , if necessary.
CAUTION!
►
Ensure that the appliance is disconnected
from the compressed air source before you fit
or remove the front connector .
♦
If necessary, unscrew the mouthpiece from
the front connector using the assembly
spanner . Afterwards, screw the correct spare
mouthpiece into the front connector and
tighten it.
♦
To attach the front connector , press it onto
the thread (you will feel minor resistance) and
tighten it by hand.
♦
Tighten the front connector using the
assembly spanner .
♦
Reconnect the appliance to the compressed air
supply.
♦
Place the rivet body in the drill hole.
♦
Slide the appliance over the rivet until the
mandrel is fully inserted into the mouthpiece .
♦
Pull the trigger . The mandrel is pulled into
the device, detached from the rivet body and
the rivet joint is established permanently.
If necessary, repeat the process until the
mandrel has been fully separated from the
rivet body.
NOTE
►
You will need to tip the appliance to the rear
to get the mandrel into the waste collector .
♦
Proceed in the same way with the other
rivets .
♦
Empty the pin collector regularly.
♦
When you have finished working, disconnect
the appliance from the compressed air source.
Содержание PDBNP 14 B1
Страница 3: ...A B ...