background image

 

WARNING!

 

u

This product produces an electromagnetic 

field during operation! This field may under 

some circumstances interfere with active or 

passive medical implants! To reduce the risk 

of serious or fatal injury, we recommend 

persons with medical implants to consult their 

doctor and the medical implant manufacturer 

before operating this product!

 

Q

Initial use

 

Q

Unpacking

 

WARNING!

 

u

The product and the packaging are not 

children’s toys! Children must not play with 

plastic bags, sheets and small parts! There is 

a danger of choking and suffocation!

1.  Unpack all parts and lay them on a flat, 

stable surface.

2.  Remove all packing materials and shipping 

devices if applicable.

3.  Make sure the delivery contents are complete 

and free of any damage. If you find that 

parts are missing or show damage do not 

use the product but contact your dealer. Do 

not use the product unless missing parts have 

been delivered in addition or defective parts 

have been replaced. Using an incomplete 

or damaged product represents a hazard to 

people and property.

4.  Ensure that you have all the accessories and 

tools needed for assembly and operation. 

This also includes suitable personal protective 

equipment.

 

Q

Accessories

To operate this product safely and correctly, the 

following accessories, i. e. tools and attachments, 

are necessary:

 

o

Suitable personal protective equipment

Ensure that you have the accessories and 

tools needed for commissioning and operation 

available. This also includes suitable personal 

protective equipment.

Accessories and tools are available through your 

authorised dealer. When buying always consider 

the technical requirements of this product (see 

“Technical data”).

If you are not certain, ask a qualified specialist and 

get advice from your trusted dealer.

NOTE

 

u

This instruction manual contains information 

and suggestions for several attachments and 

their uses. The attachments depicted are not 

necessarily included in the shipment, but are 

meant to indicate additional possibilities for 

using this product.

 

Q

Before use

 

Q

Removing / attaching blades

 

WARNING!

Always switch the product off and 

disconnect it from the mains before 

performing inspections, installing 

accessories or making adjustments!

 

WARNING!

 

u

Always use the correct blade according 

to the intended use! Observe the technical 

requirements of this product (see “Technical 

data”) when purchasing and using blades! 

Blades are very sharp and become hot 

during use! Handle them carefully! Wear 

safety gloves when handling blades in order 

to avoid injuries like burns and cuts!

 

u

Never press the spindle lock whilst the 

spindle is rotating! The arrow on the blade 

must correspond to the arrow showing the 

direction of rotation (running direction shown 

on the product).

 

u

Ensure that the blade is suitable for the 

rotational speed of the product.

1.  Press the spindle lock button 

16

 to lock the 

spindle 

17

.

2.  Use the provided multi-tool 

22

 to loosen and 

remove the blade bolt 

9

 and locking flange 

10

 (see fig. C)

3.  Lift the lower blade guard 

8

 by using the 

lower blade guard lever 

11

 and hold it in 

position (see fig. D).

4.  Remove the outer blade (marked “B“) from its 

drive flange 

18

 

, then the inner blade (marked 

“A“) from its drive flange 

19

 

.

Follow the above procedure in reverse order to 

attach blades.

12  GB / IE / NI

Содержание PDBG 125 A1

Страница 1: ...and Safety Notes Translation of the original instructions OWIM GmbH Co KG Stiftsbergstra e 1 DE 74167 Neckarsulm GERMANY Model No HG03284 BS Version 11 2017 TWIN BLADE CIRCULAR SAW PDBG 125 A1 IAN 292...

Страница 2: ...B 22 23 A B 21 20 24 22 9 C D 8 11 1 2 4 3 18 20 17 19 21 E 4 23 3 F 24 12 A 2 3 7 8 9 11 13 14 12 10 4 5 6 1 17 18 19 16 15 I G 5 6 H J...

Страница 3: ...al risks Page 11 Initial use Page 12 Unpacking Page 12 Accessories Page 12 Before use Page 12 Removing attaching blades Page 12 Lubrication Page 13 Attaching removing a dust extraction device Page 13...

Страница 4: ...art of the product They contain important information concerning safety use and disposal Before using the product please familiarise yourself with all of the safety information and instructions for us...

Страница 5: ...age frequency 230 240 V 50 Hz Rated power 1200 W No load speed n0 5500 min 1 Blade diameter 125 mm Inner blade arbor size 28 mm Outer blade arbor size 12 mm Max blade width 1 6 mm Max cutting depth 31...

Страница 6: ...afety 1 Power tool plugs must match the outlet Never modify the plug in any way Do not use any adapter plugs with earthed grounded power tools Unmodified plugs and matching outlets will reduce risk of...

Страница 7: ...d power tools 6 Keep cutting tools sharp and clean Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control 7 Use the power tool accessories and too...

Страница 8: ...workpiece as the saw is restarted 4 Support large panels to minimise the risk of blade pinching and kickback Large panels tend to sag under their own weight Supports must be placed under the panel on...

Страница 9: ...regular basis to let the blade tips cool down Q Q Vibration and noise reduction To reduce the impact of noise and vibration emission limit the time of operation use low vibration and low noise operat...

Страница 10: ...ols are available through your authorised dealer When buying always consider the technical requirements of this product see Technical data If you are not certain ask a qualified specialist and get adv...

Страница 11: ...raction adaptor 24 after work by simply pulling it off Q Q Operation CAUTION RISK OF INJURY u u Keep your hands away from the tool when the product is in operation Q Q Cutting guide The cutting guide...

Страница 12: ...each o o In particular clean the air vents after every use with a cloth and brush o o Remove stubborn dirt with high pressure air max 3 bar NOTE u u Do not use chemical alkaline abrasive or other aggr...

Страница 13: ...duct from the workpiece and switch it on again Excessive vibration or noise Accessory is dull damaged Replace with a new one Bolts nuts are loose Tighten bolts nuts Q Q Disposal The packaging is made...

Страница 14: ...of the appliance If functional or other defects occur please contact the service department listed either by telephone or by e mail You can return a defective product to us free of charge to the servi...

Страница 15: ...te 25 Restrisiken Seite 25 Vor dem ersten Gebrauch Seite 25 Auspacken Seite 25 Zubeh r Seite 25 Vor dem Gebrauch Seite 26 Entnehmen Einsetzen von Bl ttern Seite 26 Schmierung Seite 26 Anschlie en abne...

Страница 16: ...nutzen au er unter Beaufsichtigung Andere Verwendungen oder Ver nderungen des Produkts gelten als nicht bestimmungsgem und k nnen zu Risiken wie Lebensgefahr Verletzungen und Besch digungen f hren F r...

Страница 17: ...ische Daten Doppelblatts ge PDBG 125 A1 Nennspannung frequenz 230 240 V 50 Hz Nennleistung 1200 W Leerlaufdrehzahl n0 5500 min 1 Blattdurchmesser 125 mm Inneres Blatt Spindeldurchmesser 28 mm u eres B...

Страница 18: ...Begriff Elektrowerkzeug bezieht sich auf netzbetriebene Elektrowerkzeuge mit Netzkabel und auf akkubetriebene Elektrowerkzeuge ohne Netzkabel Arbeitsplatz Sicherheit 1 Halten Sie Ihren Arbeitsbereich...

Страница 19: ...das Elektrowerkzeug einschalten Ein Werkzeug oder Schl ssel der sich in einem drehenden Ger teteil befindet kann zu Verletzungen f hren 5 Vermeiden Sie eine abnormale K rperhaltung Sorgen Sie f r ein...

Страница 20: ...erkst ck an einer stabilen Aufnahme Es ist wichtig das Werkst ck gut zu befestigen um die Gefahr von K rperkontakt Klemmen des S geblattes oder Verlust der Kontrolle zu minimieren 5 Fassen Sie das Ele...

Страница 21: ...l tter mit stumpfen oder falsch ausgerichteten Z hnen verursachen durch einen zu engen S gespalt eine erh hte Reibung Klemmen des S geblattes und R ckschlag 6 Ziehen Sie vor dem S gen die Schnitt Tief...

Страница 22: ...Sichern des Einsatzwerkzeuges den gleichen Durchmesser und mindestens 1 3 des Schnittdurchmessers haben Stellen Sie sicher dass fixierte Reduzierringe parallel zueinander sind Handhaben Sie Einsatzwe...

Страница 23: ...taten ihren Arzt und den Hersteller vom medizinischen Implantat zu konsultieren bevor das Produkt bedient wird Q Q Vor dem ersten Gebrauch Q Q Auspacken WARNUNG u u Das Produkt und Verpackungsmaterial...

Страница 24: ...des Hebels f r die untere Schutzhaube 11 und halten Sie diesen in Position siehe Abb D 4 Nehmen Sie das u ere Blatt markiert mit B von dessen Antriebsflansch 18 danach das innere Blatt markiert mit A...

Страница 25: ...r markierten S gelinie auf einem Restst ck aus Die Schnittf hrung zeigt an wo der Schnitt gemacht wird 1 Sichern Sie das Werkst ck mit geeigneten Mitteln 2 Halten Sie das Produkt fest mit beiden H nde...

Страница 26: ...die Oberfl chen besch digen k nnen Q Q Wartung berpr fen Sie das Produkt und Zubeh rteile z B Einsatzwerkzeuge vor und nach jeder Benutzung auf Verschlei und Besch digungen Tauschen Sie diese gegeben...

Страница 27: ...ein neues tauschen Schrauben Muttern lose Schrauben Muttern nachziehen Q Q Entsorgung Die Verpackung besteht aus umweltfreundlichen Materialien die Sie ber die rtlichen Recyclingstellen entsorgen k nn...

Страница 28: ...abteilung telefonisch oder per E Mail Ein als defekt erfasstes Produkt k nnen Sie dann unter Beif gung des Kaufbelegs Kassenbon und der Angabe worin der Mangel besteht und wann er aufgetreten ist f r...

Отзывы: