27
GB
IE
The “impact drilling” operating
mode may only be used if the key-
less chuck is not attached!
Changing the tool
The tool holder with SDS Plus adapter
allows you to change the attachment tool
easily and conveniently without use of ad-
ditional tools.
The attachment tool is freely movable for
technical reasons. This causes a concen-
tricity deviation during idling but this has
no effect on the accuracy of the bore hole
since the drill centres itself automatically
while drilling.
The device is capable of using various drill
bit types featuring a hexagonal or cylind-
rical shaft thanks to the keyless chuck with
SDS Plus adapter.
The dust protection cap (2) largely prevents
the ingress of drilling dust into the tool
holder during operation. Ensure the dust
protection cap (2) is not damaged when
inserting tools.
If damaged, the dust protection cap
must be replaced immediately. It is re-
commended for this to be performed
by customer service.
Inserting an SDS Plus tool
1. Unlock the SDS Plus receptor (1) by
pulling the locking sleeve (3) back-
wards.
2. Rotate the tool into the tool holder.
3. Release the locking sleeve (3)
4. Check that the tool is secure by pulling
on it. The tool exhibits some radial
play for technical reasons.
Removing an SDS Plus tool
1 Pull the locking sleeve (3) backwards
and remove the attachment tool.
Inserting tools with hexagonal
and cylindrical shafts
1. Unlock the SDS Plus receptor (1)
by pulling the locking sleeve (3)
backwards.
2. Rotate the keyless chuck with SDS
Plus adapter (17) into the tool hol-
der (1).
3. Check that the keyless chuck (17)
is securely locked by pulling on it.
The keyless chuck with SDS Plus
adapter exhibits some radial play
for technical reasons.
4. Rotate the keyless chuck (17)
counter-clockwise, until the drill
chuck aperture is large enough to
accommodate the tool.
5. Push the tool as far as possible
into the keyless chuck (17).
6. Rotate the chuck clockwise to
clamp the tool firmly.
Removing tools with hexa-
gonal and cylindrical shafts
1. To remove the tool again, rotate the key-
less chuck (1) and pull out the tool.
Removing the keyless
chuck
1 Pull the locking sleeve (3) backwards
and remove the keyless chuck.
Содержание PBHA 12 A1
Страница 3: ...1 2 3 6 5 4 12 9 11 17 10 8 16 15 14 7 10 13 7 16 1 3 1 3 17 17...
Страница 137: ...137...
Страница 147: ...147...
Страница 149: ...149...