![Parkside PAS 500 C2 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/parkside/pas-500-c2/pas-500-c2_operating-instructions-manual_759383015.webp)
12
PAS 500 C2
GB
CY
Troubleshooting
In this chapter you will receive important information for malfunction localisation
and remedies.
WARNING
Pay heed to the following safety information to avoid risks and property
damage:
►
Repairs to electrical appliances may only be carried out by specialists who
have been trained by the manufacturer. Considerable risk for the consumer
and damage to the appliance can occur as a result of incompetent repairs.
Malfunction causes and remedies
The following table will help with localising and remedying minor malfunctions:
Defect
Possible cause
Solution
The appliance
will not switch
on
The plug is not connected.
Insert the plug into the mains
power socket.
The mains power socket is not
providing power
Check the house fuses
Safety stop due to missing or
incorrectly inserted HEPA fi lter
13
or wire fi lter basket
14
Fit the HEPA-Filter
13
and/or wire
fi lter basket
14
correctly
On/Off switch
6
defective
Repair by Customer Services
Motor defective
Low or lack
of suction
Suction hose
11
or suction
pipe
12
blocked
Remove obstructions and blockages
Metal container
10
is not closed
Close the metal container
10
Metal container
10
is full
Empty the metal container
10
HEPA-Filter
13
is blocked
Clean or replace the HEPA-Filter
13
Air fi lter
15
is blocked
Clean the air fi lter
15
NOTICE
►
If you cannot solve the problem with the aforementioned methods please
contact customer service.