8
GB/IE/NI
Keep the packaging material away from small
children. There is a risk of suffocation!
Repairs or/and maintenance work must only be carried out by
qualifi ed electricians.
Only use the weld cable provided in the scope of delivery.
During operation, the device should not be positioned directly
on the wall, should not be covered or jammed between other
devices so that suffi cient air can always be absorbed through the
ventilation slats. Make sure that the device is correctly connected
to the supply voltage. Avoid any form of tensile stress of the power
cable. Disconnect the plug from the socket prior to setting up the
device in another location.
If the device is not in operation, always switch it off by pressing
the ON/OFF switch. Place the electrode holder on an insulated
surface and only remove it from the holder after allowing it to cool
down for 15 minutes.
Pay attention to the condition of the welding cable, electrode
holder and the earth terminal. Wear and tear of the insulation and
the live parts can lead to hazards and reduce the quality of the
welding work.
Arc welding creates sparks, molten metal parts and smoke.
Therefore ensure that: All fl ammable substances and/or materials
are removed from the work station and its immediate surrounding.
Ensure the work station is ventilated.
Do not weld on containers, vessels or tubes that contain or contained
fl ammable liquids or gases.
Avoid any form of direct contact with the welding
current circuit. The open circuit voltage between the electrode
holder and earth terminal can be dangerous, there is a risk of
electric shock.
Do not store or use the device in a damp or wet environment or in
the rain. Protection rating IP21S is applicable in this case.
Protect your eyes using the appropriate protective glasses
(DIN level 9–10), which are fastened to the supplied welding
mask. Wear gloves and dry protective clothing that are free of oil
and grease to protect the skin from exposure to ultraviolet radiation
of the arc.
Do not use the welding power source to defrost
pipes.
385180_2107_Inverter_Schweissgeraet_PISG_100_A1_content_LB6_GB.indb 8
385180_2107_Inverter_Schweissgeraet_PISG_100_A1_content_LB6_GB.indb 8
16.12.21 11:30
16.12.21 11:30