4
GB/IE/NI
4. Scope of delivery
• Cross cut mitre saw
• Dust bag
• Workpiece clamp
• Allen key 6 mm (C)
• Allen key 3 mm (D)
• 2 work piece supports
• Support stand
• 2 carbon brushes
• 2 batteries (AAA)
• Operating manual
5. Proper use
The cross cut mitre saw is designed to crosscut wood and plas-
tic respective of the machine’s size. The saw is not designed for
cutting firewood.
Warning!
Do not use the saw to cut materials other than those specified
described in manual.
Warning!
The supplied saw blade is only intended for the sawing of
wood! Do not use this blade for the sawing of firewood!
The equipment is to be used only for its prescribed purpose.
Any other use is deemed to be a case of misuse. The user / op-
erator and not the manufacturer will be liable for any damage
or injuries of any kind caused as a result of this.
The equipment is to be operated only with suitable saw blades.
It is prohibited to use any type of cutting-off wheel.
To use the equipment properly you must also observe the safety
information, the assembly instructions and the operating instruc-
tions to be found in this manual.
All persons who use and service the equipment have to be
acquainted with this manual and must be informed about the
equipment’s potential hazards.
It is also imperative to observe the accident prevention regula-
tions in force in your area.
The same applies for the general rules of health and safety at
work.
The manufacturer will not be liable for any changes made to the
equipment nor for any damage resulting from such changes.
Even when the equipment is used as prescribed it is still im-
possible to eliminate certain residual risk factors. The following
hazards may arise in connection with the machine’s construc-
tion and design:
• Contact with the saw blade in the uncovered saw zone.
• Reaching into the running saw blade (cut injuries).
• Kick-back of workpieces and parts of workpieces.
• Saw blade fracturing.
• Catapulting of faulty carbide tips from the saw blade.
• Damage to hearing if ear-muffs are not used as necessary.
• Harmful emissions of wood dust when used in closed rooms.
Please note that our equipment has not been designed for use
in commercial, trade or industrial applications. Our warranty
will be voided if the equipment is used in commercial, trade or
industrial businesses or for equivalent purposes.
6. Safety information
General power tool safety information
m
WARNING! Read all safety warnings, instruc-
tions, illustrations and technical data provided
with this power tool.
Failure to follow the warnings and in-
structions may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future refer-
ence.
The term “power tool” in the warnings refers to your mains-operat-
ed (corded) power tool or battery-operated (cordless) power tool.
1. Work area safety
a) Keep work area clean and well lit.
Cluttered or
dark areas invite accidents.
b) Do not operate power tools in explosive atmos-
pheres, such as in the presence of flammable
liquids, gases or dust.
Power tools create sparks
which may ignite the dust or fumes.
c) Keep children and bystanders away while op-
erating a power tool.
Distractions can cause you to
lose control.
2. Electrical safety
a) Power tool plugs must match the outlet. Never
modify the plug in any way. Do not use any
adapter plugs with earthed (grounded) power
tools.
Unmodified plugs and matching outlets will reduce
risk of electric shock.
b) Avoid body contact with earthed or grounded
surfaces, such as pipes, radiators, ranges and
refrigerators. There is an increased risk of elec-
tric shock if your body is earthed or grounded.
c) Do not expose power tools to rain or wet condi-
tions.
Water entering a power tool will increase the risk
of electric shock.
d) Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the power tool.
Keep cord away from heat, oil, sharp edges or
moving parts.
Damaged or entangled cords increase
the risk of electric shock.
e) When operating a power tool outdoors, use an
extension cord suitable for outdoor use.
Use of a
cord suitable for outdoor use reduces the risk of electric shock.
f) If operating a power tool in a damp location
is unavoidable, use a residual current device
(RCD) protected supply.
Use of an RCD reduces the
risk of electric shock.
Содержание 373880 2104
Страница 4: ...8 27 28 7 8 11 33 34 12 36 35 36 6 8a 8b 22 B 22 22a 10 29 30 5 6 9 32 25 4 13 37 31...
Страница 5: ...15 14 E E E E...
Страница 65: ...60 GR CY 1 GR CY GR CY GR CY GR CY GR CY GR CY GR CY II...
Страница 67: ...62 GR CY 4 6 mm C 3 mm D 2 2 2 AAA 5 6 m 1 a b c 2 a b c...
Страница 68: ...63 GR CY d e f 3 a b c d e f g h 4 a b c d e f g...
Страница 69: ...64 GR CY h 5 a a b 100 mm c d e f 100 mm g h i j k...
Страница 70: ...65 GR CY l m n o p q r s 1 2 3 4 5 6 EN 847 1 7 HSS 8 9 10 11 12 13 14 1 3 15 16 17 18 19 20...
Страница 71: ...66 GR CY 21 22 23 24 25 2 1 2 3 4 5 6 2006 66 7 8 9 10 11 12 13 14 15 16 17 18...
Страница 76: ...71 GR CY 10 13 7 13 4 25 37 8 9 11 m 5 14 10 1 E 2 3 4 E 50 10 6 mm 15 12 5 30 C 13 VDE DIN...
Страница 77: ...72 GR CY VDE DIN H05VV F X 220 240 V 25 m 1 5 14 2012 19 Cd Hg Pb...
Страница 78: ...73 GR CY 15...
Страница 98: ......
Страница 99: ......