![Parkside 316236 1904 Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/parkside/316236-1904/316236-1904_translation-of-the-original-instructions_759458024.webp)
24
GB
IE
Check this by placing the pump
into a vessel filled with water
and lift the float switch
(
3
) carefully by hand and
then lower it again. In this case,
you can see whether the pump
switches on and off.
- Also ensure that the separa-
tion distance between the float
switch (
3) head and the float
switch height adjustment (
2)
is not too small. In the case of a
separation distance which is too
small, trouble-free functioning
cannot be guaranteed.
- During the adjustment of the
float switch (
3), ensure that
the float switch does not contact
the floor before the pump switch
-
es off.
The pump run dry if too long a float
switch cable (
12) is chosen,
particularly if the float switch height
adjustment (
2) is not installed
(see „Initial Operation“).
Manual mode
In manual mode, the pump does not switch
off automatically, as the float switch (
3)
is bypassed.
Position the float switch (3) vertical
-
ly upward in the float switch height
adjustment (2).
Monitor the pump constantly when
in manual mode. Switch the pump
off immediately (disconnect from
the mains) if no more water is be-
ing pumped. There is a risk of dam-
age if the pump runs dry.
Operational start-up
• Check that the pump is standing
firmly on the bottom of the shaft
or hung up safely.
• Place the pump on a brick and
not on a shaft floor, if applica
-
ble. This prevents damage to the
pump if the shaft floor is soiled.
• Check whether the pressure line
has been attached correctly and
the unused pump outlet is fully
closed.
• Avoid that the pump runs dry.
Regularly check the function
of the float switch. In case of
non-observance or if the pump
runs dry, guarantee and liability
claims are invalidated.
• Check that the electrical connec
-
tion is 230 V ~50 Hz
• Check the proper status of the
electrical plug socket and make
sure that the plug socket is suf-
ficiently fused (at least 6 A, RCD
switch). Insert the pump plug into
the plug socket and the pump is
ready for operation.
• Make sure that moisture or water
never come in contact with the
mains connection. There is a risk
of electrocution.
Cleaning/Maintenance/
Storage
Clean and maintain your equipment regu
-
larly. This will guarantee its performance
and long durability.
Ask our service centre to carry out
any work that is not described in
these instructions. Use only original
parts.
Содержание 316236 1904
Страница 3: ...1 7 2 9 4 5 6 10 9 8 8 10 3 6 3 2 13 12 3 2 12 11 11 1 7 m 12 4 1 2 ...
Страница 96: ...96 ...
Страница 98: ...98 ...
Страница 100: ...100 2019 09 06 rev02op ...