Building Regulations, Local Authority Byelaws, European and National Standards and other specifications or
regulations as they affect the installation of the stove.
It should be noted that the Building Regulations requirements may be met by adopting the relevant
recommendations given in British Standards BS 8303, BS 6461 and BS 7566 as an alternative means to achieve an
equivalent level of performance to that obtained following the guidance given in Approved Document J.
Your local Building Control Officer can advise you regarding the interpretation of the Regulations should there be
any questions.
This appliance must be installed by a Registered Installer (see Competent Persons Scheme) or approved by your
local Building Control Officer.
All works undertaken must be carried out with due care and attention to meet the requirements of the Health &
Safety code of practice and any other legislation that may have been introduced since the publication of these
instructions.
Competent Persons Scheme
Members of the following schemes may self-certify the installation of this stove. If the installer is not a member of
one of these schemes, your local Building Control Department must approve the installation.
Scheme
Web address
Telephone
APHC (Association of Plumbing and Heating
Contractors (Certification) Limited
0121 711 5030
Building Engineering Services Competence
Accreditation (BESCA Limited)
0800 652 5533
HETAS Ltd (Heating Equipment Testing and
Approval Scheme)
01684 278170
NAPIT Registration Ltd
01623 811483
NICEIC Group Ltd
0870 013 0389
Air Supply
The room or space containing this appliance needs a permanent, unobstructed air opening of at least 5940mm
²
(see
Technical Specification on Page 4 for confirmation). If a draught stabiliser is fitted, the air opening should be at least
10,680mm².
Due consideration should be given to air requirements for any other appliance in the same room or space.
Any air opening must be kept clear from blockage or obstruction.
This stove must be fitted on a hearth or base with adequate load-bearing capacity.
Appliance Opening
The opening into which this stove is fitted should be constructed wholly from non-combustible materials. The
dimensions of the opening should be
at least
those shown below.
This appliance will fit into a standard 16” fireplac
e opening if the clay fire back is removed.
Any non-combustible walls within 50mm of this appliance should be at least 200mm thick and should extend at
least 30mm above the top of the appliance and at least 1.2 metres above the hearth. Any walls more than 50mm