28
STEP 5.
Tighten the anchor screws with a socket wrench.
4.5.2. Installing the Power Supply
The power supply must be fed by a 230 V / 50 Hz or 120 V / 60 Hz electric line,
protected by a differential magnetothermal switch complying with the law provisions in
force. Connect the electric line wires to terminals L and N on the power supply.
Connect the power and - terminals to the cable leading to the barriers.
STEP 1.
Bring the necessary infrastructure to the barrier. Feed the supply cable
through the barrier base.
STEP 2.
The barrier is provided with an adapter cable for connecting it to the constant
supply. Disassemble the adapter.