18
Model Number:
SIG 224
Appliance Class 2 sub class 1 and Class 1
APPLIANCE CATEGORY
:II 2H3+
APPLIANCE GAS SUPPLY
: Natural Gas G20 20mbar
Hob
Rear left burner (rapid)
3,000 W
Front left burner (semi-rapid)
2,000 W
Rear right burner (semi-rapid)
2,000 W
Front right burner (auxiliary)
1,000 W
Technical Data
BURNER
RAPID
SEMI-RAPID
AUXILIARY
OVEN
(large)
(medium)
(small)
POSITION
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
NOMINAL THERMAL
POWER kW
3.0
0.65
2.0
0.45
1.0
0.33
3.0
1.0
NOMINAL FLOW
RATE m
3
/h
0.286
0.057
0.190
0.038
0.095
0.028
0.286 0.095
NOZZLE REFERENCE
119
Adjust.
9 6
Adjust.
7 0
Adjust.
116 Adjust.
NOMINAL THERMAL
POWER kW
2.8
0.65
2.0
0.45
1.0
0.33
3.0
1.0
NOMINAL FLOW
RATE g/h
202
43.5
144
2 9
7 2
21,5
216
7 2
NOZZLE REFERENCE
8 6
4 0
7 1
3 2
5 0
2 8
8 2
5 2
NATURAL GAS
20 mbar
TYPE OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37 mbar
1/100 mm
1/100 mm
VALUE = 49.92 MJ/Kg
VALUE = 37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
Instructions for the Installer
Dimensions
Height
900 mm
Depth
600 mm
Width
497 mm
Oven Capacity
1.7 Cu. ft
Oven
Grill Element
1,878 W
Oven light
15 W
Total rating
1,893 W
Supply voltage (50 Hz)
230-240 V
Important Safety Requirements
This appliance must be installed in accordance
with the Gas Safety (Installation and Use)
Regulations (current addition) and the I.E.E. Wiring
Regulations. Detailed recommendations are
contained in the following British Standard Codes
of Practice - B.S. 6172, B.S. 5440: Part 2 and B.S.
6891: Current Editions.
Provision for Ventilation
The room containing the cooker should have an
air supply in accordance with B.S. 5440: Part 2:
Current Editions.
The following requirements for ventilation must be
met.
The cooker should not be installed in a bed sitting
room with a volume of less than 20m
3
, if it is
installed in a room of volume less 5m
3
an air vent
of effective area of 110cm
2
is required; if it is
installed in a room of volume between 5m
3
and
10m
3
, an air vent of effective area 50cm
2
is
required, while if the volume exceeds 11m
3
no air
vent is required. However, if the room has a door
which opens directly to the outside, no air vent is
required even when the volume is between 5m
3
and 11m
3
.
If there are other fuel burning appliances in the
same room, B.S. 5440: Part. 2: Current Editions
should be consulted to determine the requisite air
vent requirements.