MAIN OVEN

Electric

Heat Input

2.5 kW

GENERAL

Ignition

H. T. Spark

Spark Gap

3-4mm

IMPORTANT - SAFETY REQUIREMENTS

This appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations
Current Editions and the I.E.E. Wiring Regulations. Detailed recommendations are contained in the
following British Standard Codes of Practice - BS.6172, BS.5440: Part 2 and B.S.6891. All British
Standards must be 'Current Editions'.

PROVISION FOR VENTILATION

This appliance is not connected to a combustion products evacuation device. It shall be installed and
connected in accordance with current installation regulations. Particular attention shall be given to the
relevant requirements regarding ventilation.
The room containing the appliance should have an air supply in accordance with BS.5440: Part 2 Current
Edition.  All rooms require an openable window or equivalent  and some rooms  will require a permanent
vent as well.  For room volumes up to 5m³  an air vent of 100 cm²  is required; for room volumes between
5m³  and 10m³ an air vent of 50cm²  is required.  If the room has a door that opens directly to the outside,
no air vent is required.  For room volumes that exceed 11m³  no air vent is required.  If there are other fuel
burning appliances in the same room, BS.5440: Part 2 Current Edition should be consulted to determine
the requisite air vent requirements.
If your cooker is in use over a long period of time you may need additional ventilation in your kitchen.  This
can be achieved by opening a window or, if an external fan or cooker hood is fitted, switching this on or to a
higher setting.

3

Содержание Ovation 60 GLa

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ......

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ......

Страница 37: ...HE TYPE OF SUPPLY AVAILABLE IN THE INTEREST OF SAFETY THIS APPLIANCE MUST BE INSTALLED AND OR SERVICED BY A COMPETENT PERSON AS STATED IN THE GAS SAFETY INSTALLATION AND USE REGULATIONS CURRENT EDITIO...

Страница 38: ...tions Weight of appliance 64 5kg Minimum distance from rear wall 5mm spacer given by pressed spacer on vent panel CONNECTIONS Gas Rear left hand side of cooker at hotplate level Rc B S P female Electr...

Страница 39: ...ding ventilation The room containing the appliance should have an air supply in accordance with BS 5440 Part 2 Current Edition All rooms require an openable window or equivalent and some rooms will re...

Страница 40: ...the appliance but less than 400mm above the hotplate then a minimum space of 100mm must be maintained between the sides of the unit and the appliance see Fig 1b Curtains must not be fitted immediatel...

Страница 41: ...n Fig 1c 2 Adjustment to suit floor conditions or height is obtained by rotating clockwise or anticlockwise the hexagonal feet wheels at the front and rear of the appliance NOTE The rear wheels must o...

Страница 42: ...a This is the centre line of the fixing bracket 3 Draw a line 100mm from the front edge of the levelling feet see Fig 2a and remove appliance from its position Mark off dimension B see Fig 2a back fro...

Страница 43: ...THED DO NOT EARTH THIS APPLIANCE TO THE GAS SUPPLY PIPING This appliance must be connected to a 230V A C 50Hz supply It is supplied with 2 metres of 15 amp 3 core cable incorporating a moulded 13 amp...

Страница 44: ...he lid and connect the pressure gauge to the rapid burner injector 3 Check the supply pressure by turning rapid burner tap on full and one other hotplate tap full on and light the appropriate burner T...

Страница 45: ...e oven fan and lamp will operate and after a short period the heat from the oven element may be felt when the oven door is opened 3 Turn off the thermostat and check that the oven fan stops and the ov...

Страница 46: ...10...

Страница 47: ...11...

Страница 48: ...12 Parkinson Cowan Bordesley Green Road Birmingham B9 4UB Drg No 311317600...

Отзывы: