PF6000X

Introduction & Warnings

This equipment is part of a large range of traffic flow products. They are designed to be easy to install, 
as all settings and internal wiring have been completed in our factory. Any of the instructions in this 
manual should only be carried out by a qualified service engineer or a competent person.

The steps outlined must be completed before the power is turned on to prevent accidents.

The following information is a guide only, and whilst we have made every effort to be accurate and 
correct there may be printing errors which we cannot be held responsible for.

With a correct installation you can expect to enjoy many years of reliable service from this product, we 
do however recommend that the product has a bi-annual service carried out by a qualified engineer. 
Please contact our service department to obtain a quote. As we manufacture the products we are best 
suited to care for your equipment. 

/

    

/

20

!

Important Safety Notice

Automatic barriers are designed to Control the flow of vehicular 
traffic only. It can be dangerous to allow the passage of 
pedestrians and any other self-powered animal or device to utilise 
this method of access without appropriate warnings and or 
signage.
It may be necessary for the end user of this product to provide an 
alternative, safe method of access to cater for the previously 
mentioned categories.
The end user should fit all necessary signage and warning notices 
to either side of the gate, which should be visible and clear from 
all directions of approach.
The product that was shipped to you was designed with a control 
program to protect all categories from harm or affect this however 
is only a fail safe and should not be modified or tampered with by 
any unauthorised person not sanctioned by the manufacturer.

Please sign and date below to say that you have read and 
understood this notice before ANY installation work:

Information on using
this manual

Ÿ

Read all information thoroughly

Ÿ

Pay attention to all safety advice

Ÿ

Be aware of the symbols (shown above right and above 

left) as they have different meanings. One is an 
information symbol, the other a warning.

Ÿ

There are many artists impressions of the product in 

this manual you should refer to the images as a guide 
only. 

Professional CAD

 drawings should be used as a 

reference drawing and nothing else. As before every 
effort has been made to be 100% accurate in this 
manual but we cannot make any guarantees.

Ÿ

As we constantly innovate our products we may 

change the quoted spec and any other details that have 
been documented in this manual so you should always 
refer to the supplier to see if the manual that was 
shipped with your product is the latest edition.

Ÿ

As with all electrical installations you should use a 

qualified electrician and obey all of the latest laws and 
regulations.

Ÿ

Be sure to fill out and complete 

ALL

 paperwork where 

instructed as this manual is the equipments log book 
and maintenance manual.

 The “Warnings” leaflet and “Instruction booklet” supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
 Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
 Keep the instructions together with the technical brochure for future
reference.
 This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
 The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
 Do not install the product in explosive atmosphere.
 The construction components of this product must comply with the
European Directives noted in this manual and subsequent amendments. As for all non-EEC 
countries, the abovementioned standards as well as the current national standards should
be respected in order to achieve a good safety level.

 The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing
closing structures (door, gates etc.), as well as from any deformation
which might occur during use.
 The installation must comply with the provisions set out by the European 
Directives  and subsequent amendments.
 Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3mm.
 Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
 Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
 Fit all the safety devices (photocells, electric edges etc.) which are
needed to protect the area from any danger caused by squashing,
conveying and shearing, according to and in compliance with the
applicable directives and technical standards.

Содержание PF6000X

Страница 1: ...PF6000X Automatic Barrier Rev 1 0 Installation Operation Maintenance Manual ...

Страница 2: ...G 11 13 MANUAL RELEASE GUIDE 14 STRAINING WIRE ASSEMBLY 15 FIRST OPERATION MANOEUVRES 16 LIMIT SWITCH ADJUSTMENT 17 PLC USAGE EXPLAINED 18 UPLOADING A PROGRAM 19 PLC LOGIC 20 ALTERING BARRIER SPEED 21 EXAMPLE LOOP INSTALLATION 22 LOOP DETECTOR GUIDE 23 24 WIRING DIAGRAM 25 26 MASTER SLAVE WIRING 27 TROUBLESHOOTING 28 29 BARRIER MAINTENANCE 30 POTENTIAL SYSTEM HAZARDS 31 INSTALLATION CHECK LIST 32 ...

Страница 3: ...y other details that have been documented in this manual so you should always refer to the supplier to see if the manual that was shipped with your product is the latest edition Ÿ As with all electrical installations you should use a qualified electrician and obey all of the latest laws and regulations Ÿ Be sure to fill out and complete ALL paperwork where instructed as this manual is the equipments...

Страница 4: ...he combination of products in the customer s application or use of the products At the customer s request Schneider will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product machine syst...

Страница 5: ...tion of goods and the hazards this generates It covered the main areas that cause the majority of injuries and ill health to workers including Workplace transport Slips trips and Musculoskeletal disorders MSD The movement of goods presents us as health and safety regulators with the challenge of dealing with a huge variety of issues The commercial organisations involved within the movement of good...

Страница 6: ...6000X Barrier Setup Safety Road Loop Traf Traf fic Barrier fic Barrier Loop Detector Input Mains Power Free Exit Road Loop Safety Road Loop Loop Detector Input Mains Power Access Control Pedestal ENTRY EXIT ...

Страница 7: ...est Keypad Swipe Card etc 2 Barrier Raised 3 Barrier No Passage timer started 4 Should No Passage Timer elapse before safety loop seen go to 9 5 Car move onto safety loop free exit loop inhibited no passage timer cancelled 6 Car moves o ffsafety loop 7 Car move onto free exit loop 8 Car moves o ffof free exit loop 9 Free exit loop active again 10 Barrier Lowered A2B Sequence Leave Site 1 Car moves o...

Страница 8: ...on Rusting Ÿ 3 Phase Motor for Guaranteed Reliability Ÿ Adjustable Speed Acceleration Deceleration Ÿ No Springs Required No Balancing or Adjustment Necessary Ÿ Motor Gearbox No Pulleys or Belts Required Ÿ Plug in Loop Detector Bases for Single Channel Safety Entry Exit Control Ÿ Manual Override in case of Power Failure Ÿ Comes Complete with Anchor Bolts No Cabinet Mounting Plate Required Ÿ Safety ...

Страница 9: ...n and that the duct is in the centre of the base plate 3 Using one M12 16 fixing bolt down the main cabinet using one of the holes 4 Now make sure that the barrier is now aligned perfectly continue to bolt down through the other holes using the remaining M12 16 bolts see below Now move on to step 5 The numbers in the text document below relate to the drawings below 3 1 2 4 45 mins 60 5 10 15 20 25 ...

Страница 10: ...DAPTOR AT THE SAME TIME 5 6 Now it is time to fit the pole to the barrier you must drill through the pole AFTER you have slid it onto arm using a 6mm HSS drill bit The holes should be drilled at 60mm then 200mm from the knuckle as shown above These measurements have been supplied to maintain the optimum strength of the pole arm adaptor Also please note that the pole is a precise fit so may need a de...

Страница 11: ...PF6000X Handing Change Procedure ...

Страница 12: ...PF6000X Handing Change Procedure ...

Страница 13: ...PF6000X Handing Change Procedure ...

Страница 14: ...PF6000X Barrier Manual Release Procedure ...

Страница 15: ...PF6000X Straining Wire Assembly ...

Страница 16: ...ting guide on page 11 when the screen says RUN LD follow below 3 To make the barrier move upwards or to open press the up arrow 4 To make the barrier move down or to close press the down arrow Please note that the above 2 manoeuvres will not work if there is something in the way of photocells or on the loops 1 2 3 4 Key switch keys This key switch is mounted on the side of the barrier Key switch W...

Страница 17: ...adjust Lower limit switch trigger position Set barrier to Open position Loosen limit striker Move striker to desired position Re tighten limit striker Use a rubber mallet to advance the striker in small increments to fine tune the position of the pole arm To adjust Upper limit switch trigger position Set barrier to closed position Loosen limit striker Move striker to desired position Re tighten lim...

Страница 18: ...I1 I4 Outputs Q1 Q4 Relay 8A 1 2 4 3 Memory card slot Outputs Inputs Power Inputs Left Right Up Down Menu Ok LCD Screen Green Button Menu Ok SR2 B121BD 1 2 Q1 1 2 Q2 1 2 Q3 1 2 Q4 I1 I2 I3 I4 IB ID IC IE 24VDC 24VDC 24VDC Analog or IB IE Inputs I1 I4 Outputs Q1 Q4 Relay 8A Menu Ok SR2 B121BD 1 2 Q1 1 2 Q2 1 2 Q3 1 2 Q4 I1 I2 I3 I4 IB ID IC IE 24VDC 24VDC 24VDC Analog or IB IE Inputs I1 I4 Outputs ...

Страница 19: ...pen Free entry Free exit loop Detecting vehicle on free exit entry loop Barrier opens when vehicle present on loop ID Normally Closed Lower limit Arm has reached fully closed position Lower limit switch active IE Normally Closed Safety Edge Input Photocell Input Photocell Active or Safety Edge Active 2 Outputs Output Polarity Connected to Operation when active Q1 Normally Open Motor controller ope...

Страница 20: ...al 7 The current speed is then shown Example 50 8 Now use the scroll dial to set the desired speed you require 9 Note if this is increased decreased considerably then the ACC and the DEC will also need to be adjusted to suit For any advice please contact the service department 10 Press the ESC button un l RDY is shown in the display to exit the menu ACC is set to 2 by default this may be increased...

Страница 21: ...be twisted a minimum 10 times per meter can be up to 250m long The loop must be placed at least 5m away from high tension cables and at least 1m away from low tension cables If the loop is placed in an area with reinforcing iron typically a concrete floor the loop must be placed at least 50mm above the reinforcement If the detector is used for detecting high vehicles lorries etc use only one loop f...

Страница 22: ...loop is faulty This LED can also be used to determine the loop frequence On reset cunt the number of times the LED flashes Multiply this number by 10KHz For example if the LED flashes 6 times then the loop frequency is between 60KHz and 70KHZ Loop Fault Indicator This LED indicator is illuminated when the loop is either open circuit or short circuit and is used to give a visual indication of a fault...

Страница 23: ...PF6000X Loop Detector Guide Relay Functionality Diagnostics ...

Страница 24: ... 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 L N E ESC STOP EDIT RUN MODE L0 L0 COM LI1 LI2 LI3 LI4 24V R1A R1B R1C COM A 1 5V A01 W T3 V T2 U T1 R L1 S L2 N EARTH Y G 1 2 Q1 1 2 Q2 1 2 Q3 1 2 Q4 Safety Loop Free Entry Exit Loop Inverter PLC LNE 10 11 6 1 2 A2 31 21 11 A1 34 32 24 22 14 12 9 8 7 5 3 4 ...

Страница 25: ... LOWER RAISE LIMIT COM RAISE LIMIT LOWER LIMIT COM COM PHOTOCELL FLASHING LIGHT TRAFFIC LIGHT SAFETY EDGE SWITCH LOWER LIMIT LOOP EARTH MOTOR WIRE MOTOR WIRE MOTOR WIRE LIVE NEUTRAL EARTH 20 21 22 23 24 L N E 24V 24V LOOP LOOP LOOP SAFETY SAFETY FREE EXIT FREE EXIT PF6000X Wiring Diagram ...

Страница 26: ...ust requires a link between the PLC inputs 1 Link 24v negative between PLC s DO NOT LINK positive 2 Link I1 between PLC s Stop Command 3 Link I2 between PLC s Open Command 4 Link I3 between PLC s Close Command 5 Link IB between PLC s Safety Loop just needed in master barrier only 6 Link IC between PLC s Free Entry Exit Loop Just needed in master barrier only 7 Link IE between PLC s Photocells If u...

Страница 27: ...PF6000X Wiring Diagram LED and Safey edge Wiring When you receive your barrier you need to connect the safety edge and LED lights ...

Страница 28: ...PF6000X Safety Edge Setup ...

Страница 29: ...PF6000X Safety Edge Setup ...

Страница 30: ...se can be provided by your supplier Safety Edge Should be showing 8 2KΩ Barrier not going up Access control may be faulty Remove and check barrier function via the PLC Barrier Staying up Car has driven o ffbefore clearing the loop Complete cycle by going through the ground loop Stop Circuit Broken displaying on screen Circuit Broken Check Link between I1 I2 Barrier staying open and not closing If p...

Страница 31: ...g or replace loop MECHANICAL ERRORS CAUSE CORRECTION 1 If the barrier has a permenant raise signal for over 2 minutes the PLC display will show PERMANENT RAISE SIGNAL 2 If the Free Exit Entry Loop Detector has a constant signal the PLC display will show CHECK FREE EXIT LOOP DETECTOR 3 If the barrier has photocells or a safety edge connected and they are faulty the PLC display will show CHECK PHOTO...

Страница 32: ...mer Site Address Postcode Contact Contact Number Check safety device and equipment Ensure ground anchor is stable and secure Check all electrical connections Check motor and fixings Check pole arm adaptor and fixings Check pole for damage and signs of stress Check end rest is secure and functional Check reader post is securely fixed and cold holder etc are functioning Check for visual damage Check an...

Страница 33: ...mers site This is in no way a health and safety guide just a few key areas for you to be aware of and possibly make future changes to Plan view from above Sketch system layout detailing and numbering potential hazard areas for the client Potential Hazard Areas see diagram 1 2 3 4 5 Additional Comments Descriptions concerning safety on this site Signed ...

Страница 34: ...ing instructions undertaken Product works the way site need it to this includes no passage time out etc System has had the completed conformity certificate All items on the delivery note have been handed over to client site this should be signed for on the separate sheet which is titled Delivery Note green or yellow paper if parts missing call supplier The engineer has expressed the importance of r...

Страница 35: ...accordance with the guidelines below at any point service repair work is carried out on the product This is to achieve two things 1 To keep a history of the product for yourself and your supplier manufacturer 2 To keep an accurate log of any historical or recent modifications and or problems to help an engineer in the event of any future work required on the product ...

Страница 36: ...ordance with the following documents Document Ref Revision Description PF6000Lux O M 4 2 System guides and drawings as defined within O M Manuals Part 4 The following test procedures refer Check Lists pages 15 16 Commissioning Certificate Part 5 Existing Installation Items not covered under warranty This certificate Installers Name On Behalf of Address Signature Date of Signing Position Parts Handed ...

Страница 37: ...tibility Directive 2004 108 EC and the CE Marking Directive 93 68 EC The equipment has been designed to meet the following standards Electrical Safety BS EN 60204 1 2006 A1 2009 BS 7671 2008 A1 20011 A2 2013 BS EN 62061 2005 A1 2013 BS EN 61439 1 2011 BS EN 61439 2 2011 BS EN 12978 2003 A1 2009 Mechanical Safety PD5304 2014 BS EN ISO 12100 2010 BS EN 60529 1992 A2 2013 BS EN ISO 13849 1 2008 BS EN...

Страница 38: ...PEAN MARK CERTIFYING CONFORMITY TO THE ESSENTIAL REQUIREMENTS OF THE STANDARDS 2006 42 EC Proudly Made in the UK Proudly Made Made using recycled paper The manufacturer reserves the right to make amendments to this manual without prior notice and declines all responsibility for any errors personal injury or damage to property ...

Отзывы:

Похожие инструкции для PF6000X