162 VIX IM MICROSTEPPER INDEXER DRIVE USER GUIDE
RFS
Return to factory settings
Syntax
Units
Range of ‘n’
Default
See also
aRFS
-
-
-
SV
Description
Issuing an RFS command initialises the controller to factory default settings.
The drive must be de-energised (OFF) for RFS to be executed.
Factory settings must be saved using the SV command before they take
effect.
The default settings are:
All labels cleared, all outputs set to logic low.
Note: the RFS state of ARM is start disabled, fault enabled (ARM01).
Properties
Immediate, can’t be used in labelled block, saved by SV
Example
1LIMITS(3,0,0,900)
;define limits
1RFS
;return to factory settings
1SV
;save factory settings
1LIMITS
;report limits
*LM0 TP1 M0 AD 200