C o n f i d e n t i a l P a r k e r S e a R e c o v e r y
0 6 1 2 2 0 1 7
As the upstream seawater RO watermaker starts and stops, the ULTROclear also turns on and off
for simple and reliable two-pass ultrapure RO operation.
Standard Design Conditions
Supply pressure 20 to 60 psi
o
Note: An internal pressure relief valve is installed in the UC and set at
approximately 60 psi. If the feed water pressure at the Filter OUT pressure gauge
is over 55 psi, feed water will bypass around the UC system through the pressure
relief valve to the final product line.
Source water conductivity, design 1,000 microsiemens, max 2,500 microsiemens, with
derated capacity (650 to 1,250 mg/L TDS)
Product water maximum flow of 400 gpd (17gph), 800 gpd (33gph), 1,200 gpd (50gph),
or 1,500 gpd (62gph), refer to the model rating.
RO recovery of approximately 65-90% (adjustable), as P2 RO
o
CAUTION: With increased recovery, membrane life will be reduced
Product water pressure, 0 to 25 psi
Brine pressure, 0-20 psi
UC Feed Power: 2 amp (230V) & 3 amp (110V)
Typical operating power: less than 175 watts (low energy under ¼ hp)
100 to 230V, 1 phase, 50 – 60 hz
Common Options:
A. Mounting pads for the low pressure RO unit:
a. (4) 2115030120
b. (4) 061142150020
c. (4) 061100049000
d. Note: Holes can be drilled into the base of the frame for mounting, as
applicable for the installation.
B. RO product water neutralizing filter (drinking water), P/N: B561080001 (change
1x/month, typ.)
C. Handheld TDS meter, P/N: 99-1990
D. Handheld multi-parameter meter, P/N: 91-3557 (ph, ORP, TDS, cond, temp.,
resistivity)
E. Prefilter sediment/carbon: 0803004773 (change 1x/month, typ.)
F. Cleaner 1 cartridge: 40012002 (clean 1x/1-3months)
G. Cleaner 2 cartridge: 40012003 (clean 1x/1-3months)
H. Preservative cartridge: 40012018 (preserve when not in regular use)
I.
RO lubricant: PN:21-1122 (recommended: 10 min)
J. RO feed 3-way inlet valve for two feed water sources (a) direct watermaker feed and
(b) feed from dock-side potable water or the boats potable distribution system.
Contact Parker engineering.
General Service Guidelines