Nominal Product/Permeate flow ratings for each ULTROclear DF model are noted below.
ZK-A1F
One vessel rated flow
400 gpd / 17 gph max
ZK-A2F
Two vessel rated flow
800 gpd / 33 gph max
ZK-A3F
Three vessel rated flow
1,200 gpd / 50 gph max
ZK-A4F
Four vessel rated flow
1,500 gpd / 62 gph max
Typical Filter Out Pressure:
20 to 50 psi
Typical Membrane Pressure range:
75 to 130 psi
Typical operation for a ZK-A2F system is shown below producing 30 gph of RO
PRODUCT
water at 42 psi Filter OUT pressure