Installation Instructions for 4041-5300 Electrical Connection Kit
for Self-Regulating Bundles
4
Parker Hannifin Corporation
Parflex Division
Ravenna, OH USA
www.parker.com/pfd
Instructions for Splice or Tee Connections (Continued)
7
8
9
The exposed tube and heating cable
area between bundles should be
reinsulated and sealed using a
Parker SK-612 Seal Patch Kit
provided. Additional SK kits
available in 3 different sizes at
your local Parker Instrumentation
Distributor.
Make electric splice connection
inside box with heating cables from
each bundle. Using two butt splice
connectors, splice together heater
bus wires. Follow “Heating Cable
Preparation” at end of manual.
Using ring terminals, crimp terminal
rings onto braided pigtails and
tighten to back of box with ground
screw. Note: One ground screw may
be used for both wires if necessary.
Wrap bus wire connections with
fiberglass tape. Bus wire connections
must not touch inside box, otherwise
a short circuit will occur.
Braided Ground
Wire
FG Tape
Butt Splice (before
FG tape applied)
Slide silicone rubber grommet
and seal fitting compression ring
forward until it is flush with the
junction box side port; tighten until
metal cap bottoms out on cable
entry fitting.
Plug top port with 3/4" conduit plug.
Tighten Metal Cap
Typical Splice – T Connection
Please follow steps 1-8 in “Instructions for Splice or Tee Connections,” except use a
Tee union fitting available from your local Parker Instrumentation Distributor to bring
in an additional bundle. Utilize top port of junction box with splice or Tee connection.
SK-612
SK-612
Typical Splice Connection
Tube fittings are available from
your local Parker Instrumentation
Distributor.
SK-612
Tube Fittings