background image

Valve

Port Size

Connection

Flow Coefficient 
(control module)

Flow Coefficient 
(complete valve)

mm

inch

SW

BW (ANSI / DIN)

k

V

c

V

k

V

c

V

S8VS

15

1

/

2

"

1

/

2

", 

3

/

4

"

1

/

2

", 

3

/

4

" / DN15, DN20

2.3

2.7

2.28

2.63

S8ST

15

1

/

2

"

1

/

2

", 

3

/

4

"

1

/

2

", 

3

/

4

" / DN15, DN20

2.3

2.7

2.28

2.63

Table of Contents

Technical Data    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

Electrical  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

Function and Design   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

Manual Opening Stem Operation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

Material List: Isolation Valve (Hand Shutoff)    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

Material List: Strainer    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

Material List: Solenoid    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5

Material List: Expansion Valve    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5

Installation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

Nameplate Information    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

Maintenance and Service     .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7

Dimensional Information  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8

Clearance Zone 152 .40 [6 .00]  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8

Parts Kit Reference   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10

Technical Data 

Liquid Temperature Range    .  .  .  .  .  .  .  -50°C to 105°C (-58°F to 221°F)

Ambient Temperature Range    .  .  .  .  .  .  -50°C to 60°C (-58°F to 140°F)

Maximum Rated Pressure (MRP)   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  32 bar (465 psig)

Maximum Operating Pressure Diff . (MOPD)    .  .  .  .  21 bar (305 psid)

Burst Pressure   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  > 5 x MRP

Coil Classification    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  Class H; NEMA 4

Bulletin 10-02

2

Electrical

The Parker Refrigerating Specialties Division molded water 
resistant Class “F” solenoid coil is designed for long life and 
powerful opening force . The standard coil housing meets 
NEMA 4 requirements . This sealed construction can withstand 
direct contact with moisture and ice . By def nition, Class “F” 
coil construction will permit coil temperatures, as measured 
by resistance method, as high as 155°C (311°F) . Final coil 
temperatures are a function of both fluid and ambient 
temperatures . The higher fluid temperatures require lower 
ambient temperatures for the maximum coil temperature not to 
be exceeded . Conversely, low fluid tem peratures permit higher 
ambient temperatures .

A solenoid coil should never be energized except when mounted 
on its corresponding solenoid tube .

The molded Class “F” coil is available from stock with most 
standard voltages . However, coils are available for other voltages 
and frequencies, as well as for direct current . 

The solenoid coil must be connected to electrical lines with Volts 
and Hertz same as stamped on the coil . The supply circuits must 
be properly sized to give adequate voltage at the coil leads even 
when other electrical equipment is operating . The coil is designed 
to operate with line voltage from 85% to 110% of rated coil voltage . 
Operating with a line voltage above or below these limits may 
result in coil burn-out . Also, operating with line voltage below 
the limit will defnitely result in lowering the valve’s maximum 
opening pressure differential . Power consumption during nor mal 
operation will be 35 watts or less . 

Table 1: 

General Coil Information

Coil Features

•  Leaded coils are provided with 18 gage wires at 

457 mm (18") in length .

•  Both leaded and DIN quick disconnect (QD) coil 

are Nema 4x .

•  Optional LED knobs that indicate when the coil 

is energized are available in red or green for AC 
coils only .

Coil 

(Volts/Hz)

Power

Lead

Neutral

Lead

Inrush

Current

(Amps)

Running

Current

(Amps)

Fuse Size

(Amps)

Temp

ºC (ºF)

24/50

Brown

White

6.82

2.99

4

250 (482)

24/60

Brown

White

6.70

2.73

4

250 (482)

115/50

Purple

White

1.22

0.21

1

90 (194)

120/60

Blue

White

1.18

0.46

1

90 (194)

208/60

Red

White

0.63

0.24

1

90 (194)

230/50

Yellow

White

0.65

0.26

1

90 (194)

240/50

Black

White

0.59

0.24

1

90 (194)

240/60

Orange

White

0.60

0.23

1

98 (208)

12 DC

Brown

White

24 DC

Brown

White

6.70

6.70

204 (400)

Содержание S8VS

Страница 1: ...nates the need to order and install additional components The S8VS valve station is based on the proven S8F solenoid valves RSF strainers and R S hand valves The S8ST solenoid strainer combination val...

Страница 2: ...ceeded Conversely low fluid tem peratures permit higher ambient temperatures A solenoid coil should never be energized except when mounted on its corresponding solenoid tube The molded Class F coil is...

Страница 3: ...t and valve outlet allows the main valve to be lifted A minimum pressure difference of approximately 1 psi is required for operation Stop Check Expansion Module Position 4 features a isolation valve w...

Страница 4: ...3 Nut Packing 303 Stainless Steel 4 Packing Gland PTFE Carbon Filled 5 Packing Style 235A Crane Foil 6 Bonnet Hand Valve Steel Zinc Plated A350 LF2 Class 1 7 Disc Carrier Hand Valve 1117 Stainless St...

Страница 5: ...Aluminum 2011 T3 per ASTM B211 2 Stem Hand Valve 303 Stainless Steel 3 Nut Packing 303 Stainless Steel 4 Packing Gland PTFE Carbon Filled 5 Packing Style 235A Crane Foil 6 Bonnet Hand Valve Steel Zin...

Страница 6: ...arefully Check the carton to make sure all items are unpacked Save the enclosed instruction for the installer and eventual user Do not remove the protective coverings from the inlet and outlet of the...

Страница 7: ...be remedied by replacing the valve seat or by cleaning the seat Valve is installed backwards This can be remedied by removing the valve from the system and reinstalling in the correct orientation Stra...

Страница 8: ...tion mm inch Figure 5 S8VS Dimensional Diagram Figure 6 S8ST Dimensional Diagram Bulletin 10 02 8 146 18 5 76 56 41 2 22 164 12 6 46 117 30 4 62 234 95 9 25 Clearance Zone 152 40 6 00 164 12 6 46 112...

Страница 9: ...T Butt Weld BW ANSI Port Size Connection T OD mm inch mm inch mm inch 15 1 2 1 2 3 9 0 152 21 6 0 850 3 4 4 0 0 159 26 9 1 060 BW Butt Weld ANSI OD T Butt Weld BW Metric Port Size Connection T OD mm...

Страница 10: ...embly Gasket Solenoid Plunger Kit AC Coil DC Coil 201019 201021 6 7 8 Gasket Solenoid Piston Seat Piston Seat Kit 210562 6 10 Gasket Solenoid Tube Assembly Gasket Kit 209322 9 10 Seal Cap Gasket Seal...

Страница 11: ...ube Kit Standard DN 209320 209321 5 6 Plunger Needle Assembly Gasket Solenoid Plunger Kit AC Coil DC Coil 201019 201021 6 7 8 Gasket Solenoid Piston Seat Piston Seat Kit 210562 6 10 Gasket Solenoid Tu...

Страница 12: ...langes with ODS connections are not suitable for ammonia service Warranty All Refrigerating Specialties products are under warranty against defects in workmanship and materials for a period of one yea...

Отзывы: