8
Proportional Pressure Valves
Series RE*T / R*V
Operation Manual
Parker Hannifin Corporation
RE_-R_V obe_24-45-A-B 5715-651 UK 29.01.19
Parker R*V / RE*T pressure valves have an integral
electronic and requires only one sole electrical
common for the control system. Different flow sizes,
as well as command signal options are available
to achieve an optimal adaption for different appli-
cations.
Block diagram of integral elektronics
Code F/10V
Code G/R/4MA
Characteristics of Valve Driver
The described integral electronic driver combines
all necessary functions for the optimal operation of
the valve. The most important features are:
• digital circuit design
• high dynamic constant current solenoid con-
trol
• differential input stage with various command
signal options
• two quadrant ramp function
• MIN adjustment for deadband compensation
• MAX adjustment to match the command signal
span to the valve operating range
• optional reference outputs 10 V for potentio-
meter supply
• standard central connection
• compatible to the relevant European EMC-
standards
• comfortable interface program
RE06M*T
Parametrizing connector
Central connector
Air bleeding