1.8 Phastite Assembly
1.8.1
Permanent Straight Phastite Connectors.
A. Parker Phastite Connectors are supplied completely assembled and disassembly
of the collar should not be attempted.
B. Insert the tube into the Parker Phastite Connector, ensuring that adequate tube
insertion is achieved, see 1.5 for details.
C. Align the Phastite Connector into the tool ensuring that the Connector is
orientated to the appropriate jaw insert, see 1.2 for details.
D. Re-confirm adequate tube insertion by ensuring that both tube mark lines are
hidden under the Phastite Collar.
E. Apply pressure to the Phastite Assembly Tool, maximum pressure 700 bar
(10,000 psi). The Moving jaw will close around the connector.
F.
Continue to apply pressure until the Phastite Collar makes contact with the
Abutment Shoulder of the Phastite Connector Body.
G. Remove pressure from the tool. The Moving Jaw will automatically retract.
H. Remove connector and tube assembly from tool jaws, checking tube insertion, see 1.5 for details.