1.3 Jaw Insert assembly / disassembly:
Ensure that the correct Jaw Inserts have been selected for the size and type of Phastite connector to be assembled, and jaw (see
section 1.2).
1.3.1 PH-8-HANDTOOL / PH-8-BENCHTOOL
1.3.1.1 Assembly.
Ensure that insert and jaw are free from damage / foreign bodies.
Slide insert into jaw. Ensuring that the guide flat is facing the main body of the tool and inserted into the jaw in the direction
shown.
Once installed the insert will be retained by a self energising locking system.
1.3.1.2 Disassembly.
The insert can removed from the jaw, simply by pulling.
For smaller inserts a step is provided as shown. This can be used to remove the insert.
1.3.2 PH-16-BENCHTOOL
1.3.2.1 Assembly.
Ensure that insert and jaw are free from damage / foreign bodies.
Slide insert into jaw. Ensuring that the 2 location pins locate within the insert.
Once installed retain the insert with the small socket cap screw provided
–
tighten hand tight only.
1.3.2.2 Disassembly.
The insert can removed from the jaw, simply by removing the small socket cap screw.
1.4 Installing / Disconnecting Hose Couples.
Only the coupling between the hose assembly and the pump should be disconnected. The hose assembly to tool connection must not
be disconnected.
An appropriate hose coupling has been supplied to suit 3/8 NPT ported equipment. If replaced the coupling must be selected to suit the
pump and hose assembly and must be selected with all aspects of the application in mind. It is the user‟s responsibility to s
elect a
suitable coupling.
Fixed Jaw
Moving Jaw
Guide flat.
Insertion Direction
Step for insert removal
Fixed Jaw
Moving Jaw