Parkrimp 1 Crimper Electrical Requirements
The power supply should be brought via separate branch circuit to a single grounded receptacle. The
Parkrimp 1 unit has been shipped with a 6 ft. long cord and plug. Figure 3 shows the proper NEMA configuration
plug and receptacle approved for use with this machine.
Note:
It is against the Natoinal Electrical Code to remove the plug from the cord or to install the mating receptacle
in a system rated for less than 20 amps.
ANY CHANGES OR ELECTRICAL WORK PERFORMED ON THIS UNIT MUST ONLY BE MADE BY A
QUALIFIED ELECTRICIAN.
Model
80C-181
Phase
1
Phase
Voltage
115
Cycle
60
Hz
Full Load Amperes
16 Amps
Circuit Fuse
20 Amps
Wire size for receptacle must conform to the
requirements of the National Electrical Code or the
prevailing local code. The outlet box should be located
within the range of the provided cord.
We strongly
recommend against the use of an extension cord.
The installer
must perform a ground continuity
check
on the power outlet box to ensure it is properly
grounded.
Alternate Motor Voltages:
Full
Load
Amperes
Voltage
(Standard)
115
16
Voltage
(Alternate)
230
8
*Reference motor nameplate for wiring diagrams.
Electrical Requirements
G
G
NEMA
5-20R
NEMA
5-20P
Figure 3: NEMA Configuration of Plug and Receptacle