Programming Information
Set Proportional Band
Proportional band is used for setting the reaction sensitivity
of the regulator. The displayed value is X 10 mbar and has a
range between 50 (0.5 bar) and 250 (2.5 bar).
Set Deadband
Deadband is the minimum limit of accuracy at which the regulator
is set for normal operation. The displayed value is X 10 mbar and
has a range between 4 (40 mbar) and 40 (400 mbar).
Fine Settings
or
or
Parameter Number 12 – Set Proportional Band (P20 Must be Set to 0)
Step
1
2
3
4
5
Press
3-6 seconds
Until Display
Reads
Flashing Decimal
Flashing Decimal
(value between
50 and 250)
Flashing
Description
Accesses
changeable
parameters.
Accesses
parameter no. 12.
Displays current
parameter value.
Incremental
value is:
x 10 mbar
Edits parameter.
Accepts and
saves new
parameter
setting.
Sequences to
next parameter.
or
or
Parameter Number 13 – Set Deadband (P20 Must be Set to 0)
Step
1
2
3
4
5
Press
3-6 seconds
Until Display
Reads
Flashing Decimal
Flashing Decimal
(value between
4 and 40)
Flashing
Description
Accesses
changeable
parameters.
Accesses
parameter no. 13.
Displays current
parameter value.
Incremental
value is
x 10 mbar
Edits parameter.
Accepts and
saves new
parameter
setting.
Sequences to
next parameter.
“P3HPA” / “P3KNA” Series
Electronic Proportional Regulators