![Parker P31P Series Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/parker/p31p-series/p31p-series_technical-information_4104759013.webp)
F15
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics
F
P31P / P23P
PAR15
Catalog 0700P-E
Programming Information
P31P / P32P Series
Electronic Proportional Regulators
or
Parameter Number 39 – Displays Current Software Version
Step
1
2
3
Press
3-6 seconds
Until Display
Reads
Flashing Decimal
Description
Accesses
changeable
parameters.
Accesses
parameter no. 39.
Displays current
parameter value.
XXX = current
software version
Proportional Effect
Parameter Number 21 – Set Proportional Effect (P20 Must be Set to 0)
Step
1
2
3
4
5
Press
3-6 seconds
Until Display
Reads
Flashing Decimal
Flashing Decimal
(value between
5 and 100)
Flashing
Description
Accesses
changeable
parameters.
Accesses
parameter no. 21.
Displays current
parameter value.
Edits parameter.
5 = fastest
regulation
100 = slowest
regulation.
Accepts and
saves new
parameter
setting.
Sequences to
next parameter.
or
or
Set Deadband
Deadband is the Minimum limit of accuracy at which the regulator is set for normal operation. The displayed value is X 10 mbar and has a range
between 4 (40 mbar) and 40 (400 mbar).
or
or
Parameter Number 13 – Set Deadband (P20 Must be Set to 0)
Step
1
2
3
4
5
Press
3-6 seconds
Until Display
Reads
Flashing Decimal
Flashing Decimal
(value between
4 and 40)
Flashing
Description
Accesses
changeable
parameters.
Accesses
parameter no. 13.
Displays current
parameter value.
Incremental
value is
x 10 mbar
Edits parameter.
Accepts and saves
new parameter
setting.
Sequences to next
parameter.
www.comoso.com
www.comoso.com