![Parker](http://html1.mh-extra.com/html/parker/n-series/n-series_user-manual_3778028006.webp)
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics
M6
M
Catalog 0600P-10/USA
Model Number Index
“N” Series Valves
Inline Poppet Valve – Solenoid Operated
“N” Series 3/8", 3/4" & 1-1/4" Body Sizes - Solenoid ‘L’ Pilot
BOLD OPTIONS ARE MOST POPULAR.
Valve Function - Solenoid
3/8" & 3/4" Body
2-Way, Normally Closed
315
3-Way, Normally Closed
355
3-Way, Normally Open
375
1-1/4" Body
2-Way, Normally Closed
325
3-Way, Normally Closed
365
3-Way, Normally Open
385
N 315 3 9 0 45 53 —
Options
Blank
None
L
72" Leads - ‘51’ Voltage Code Only
C
Chrysler Wiring - Enclosure ‘J’ & ‘N’
F
Ford Wiring - Enclosure ‘E’, ‘J’, & ‘N’
G
GM wiring - Enclosure ‘J’ & ‘N’
Port Size / Thread Type
3/8" Body Size
3/8" Inlet & Cyl - 1/2" Exhaust - NPT
3
1/2" Inlet & Cyl - 1/2" Exhaust - NPT
4
1/2" Inlet & Cyl - 1/2" Exhaust - BSPP
N
3/4" Body Size
1/2" Inlet & Cyl - 3/4" Exhaust - NPT
5
3/4" Inlet & Cyl - 1" Exhaust - NPT
6
3/4" Inlet & Cyl - 1" Exhaust - BSPP
Q
1" Inlet & Cyl - 1" Exhaust - NPT
7
1-1/4" Body Size
1" Inlet & Cyl - 1 1/4"Exhaust - NPT
7
1-1/4" Inlet & Cyl – 1-1/2" Exhaust - NPT
8
1-1/4" Inlet & Cyl – 1-1/2" Exhaust - BSPP
S*
1-1/2" Inlet & Cyl – 1-1/2" Exhaust - NPT
9
1-1/2" Inlet & Cyl – 1-1/2" Exhaust - BSPP
T*
* Not available with Valve Function 325.
Note: BSPP is to the ISO 228 Standard, and
requires an R-BSPT male fitting.
Solenoid Enclosure
Basic Pilot
1
Basic Pilot NLMO
2
Basic Pilot LMO
3
Junction Box NLMO
5
Junction Box LMO
6
Junction Box NLMO w/ Light
8
Junction Box LMO w/ Light
9
Basic Pilot Ext. LMO
W
JIC NLMO w/Light - 3-Pin Automotive
E
JIC NLMO w/ Light - 4-Pin M12
J
JIC NLMO w/ Light - 5-Pin Automotive
N
“L” Pilot Code
Code
Voltage
Solenoid Enclosure Options
AC
60hz
AC
50hz DC
Standard Duty
(01, 45)
Cont. Duty
(04, 48)
200 PSI
(46)
42
24
24
6
5, 6
6
45
12
1, 5, 6
49
24 1, 2, 3, 5, 6, 8,
9, W
6, 8, 9
9
51
48
1
53
120 110
1, 2, 3, 5, 6, 8,
9, E, N, W
1, 6, 8, 9, N 8, 9, E
57
240 220
1, 3, W
61
120
5, 6
79
24
E, J
E, J
E, J
Solenoid Type
0
Standard
5*
Hazardous Duty
8*
NEMA 4 Solenoid
* Available with Solenoid Enclosure 2 & 3, ‘L’
Pilot
Configuration 04 & 48,
and Voltage 49 & 53 ONLY
.
“L” Pilot Configuration
01*
External Pilot, Std Service, 140 PSI
04*
External Pilot, Cont Duty, 140 PSI
45
Internal Pilot, Std Service, 140 PSI
46
Internal Pilot, Std Service, 200 PSI
48
Internal Pilot, Cont Duty, 140 PSI
* Not available with Valve Function 325, 365,
and 385 (1-1/4" Body).