Parker

Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics

Y11

Y

  2.7.  Chemical Compatibility: For more information on plastic component chemical compatibility see Pneumatic Division technical bulletins 

 

Tec-3, Tec-4, and Tec-5

  2.8.  Product Rupture: Product rupture can cause death, serious personal injury, and property damage. 

 

•  Do not connect pressure regulators or other Pneumatic Division products to bottled gas cylinders.

   

•  Do not exceed the maximum primary pressure rating of any pressure regulator or any system component.

   

•  Consult product labeling or product literature for pressure rating limitations.

3. PRODUCT ASSEMBLY AND INSTALLATION INSTRUCTIONS

  3.1.  Component Inspection: Prior to assembly or installation a careful examination of the valves, FRLs or vacuum products must be  

 

 

performed. All components must be checked for correct style, size, and catalog number. DO NOT use any component that displays any   

 

signs of nonconformance.

  3.2.  Installation Instructions: Parker published Installation Instructions must be followed for installation of Parker valves, FRLs and 

 

vacuum components. These instructions are provided with every Parker valve or FRL sold, or by calling 1-800-CPARKER, or at 

 

www.parker.com. 

  3.3.  Air Supply: The air supply or control medium supplied to Valves, FRLs and Vacuum components must be moisture-free if ambient  

 

 

temperature can drop below freezing

4. VALVE AND FRL MAINTENANCE AND REPLACEMENT INSTRUCTIONS

  4.1.  Maintenance: Even with proper selection and installation, valve, FRL and vacuum products service life may be significantly reduced  

 

 

without a continuing maintenance program. The severity of the application, risk potential from a component failure, and experience  

 

 

with any known failures in the application or in similar applications should determine the frequency of inspections and the servicing or    

 

replacement of Pneumatic Division products so that products are replaced before any failure occurs. A maintenance program must  

 

 

be established and followed by the user and, at minimum, must include instructions 4.2 through 4.10.

  4.2.  Installation and Service Instructions: Before attempting to service or replace any worn or damaged parts consult the appropriate 

 

Service Bulletin for the valve or FRL in question for the appropriate practices to service the unit in question. These Service and  

 

 

Installation Instructions are provided with every Parker valve and FRL sold, or are available by calling 1-800-CPARKER, or by accessing  

 

the Parker web site at www.parker.com.

  4.3.  Lockout / Tagout Procedures: Be sure to follow all required lockout and tagout procedures when servicing equipment. For more  

 

 

information see: OSHA Standard – 29 CFR, Part 1910.147, Appendix A, The Control of Hazardous Energy – (Lockout / Tagout)

  4.4.  Visual Inspection:  Any of the following conditions requires immediate system shut down and replacement of worn or damaged  

 

 

components: 

 

•  Air leakage: Look and listen to see if there are any signs of visual damage to any of the components in the system. Leakage is an  

 

 

  indication of worn or damaged components.

   

•  Damaged or degraded components: Look to see if there are any visible signs of wear or component degradation.

   

•  Kinked, crushed, or damaged hoses. Kinked hoses can result in restricted air flow and lead to unpredictable system behavior.

   

•  Any observed improper system or component function: Immediately shut down the system and correct malfunction.

   

•  Excessive dirt build-up: Dirt and clutter can mask potentially hazardous situations.

   

Caution: Leak detection solutions should be rinsed off after use.

  4.5.  Routine Maintenance Issues: 

 

•  Remove excessive dirt, grime and clutter from work areas.

   

•  Make sure all required guards and shields are in place.

  4.6.  Functional Test: Before initiating automatic operation, operate the system manually to make sure all required functions operate  

 

 

properly and safely.

  4.7.  Service or Replacement Intervals: It is the user’s responsibility to establish appropriate service intervals. Valves, FRLs and vacuum    

 

products contain components that age, harden, wear, and otherwise deteriorate over time. Environmental conditions can significantly  

 

 

accelerate this process. Valves, FRLs and vacuum components need to be serviced or replaced on routine intervals. Service intervals    

 

need to be established based on: 

 

•  Previous performance experiences.

   

•  Government and / or industrial standards.

   

•  When failures could result in unacceptable down time, equipment damage or personal injury risk.

  4.8.  Servicing or Replacing of any Worn or Damaged Parts: To avoid unpredictable system behavior that can cause death, personal  

 

 

injury and property damage: 

 

•  Follow all government, state and local safety and servicing practices prior to service including but not limited to all OSHA Lockout  

 

 

  Tagout procedures (OSHA Standard – 29 CFR, Part 1910.147, Appendix A, The Control of Hazardous Energy – Lockout / Tagout).

   

•  Disconnect electrical supply (when necessary) before installation, servicing, or conversion.

   

•  Disconnect air supply and depressurize all air lines connected to system and Pneumatic Division products before installation, service,   

 

  or  conversion.

   

•  Installation, servicing, and / or conversion of these products must be performed by knowledgeable personnel who understand how  

 

 

  pneumatic products are to be applied.

   

•  After installation, servicing, or conversions air and electrical supplies (when necessary) should be connected and the product tested    

 

  for proper function and leakage. If audible leakage is present, or if the product does not operate properly, do not put product or 

 

  system into use.

   

•  Warnings and specifications on the product should not be covered or painted over. If masking is not possible, contact your local  

 

 

  representative for replacement labels.

  4.9.  Putting Serviced System Back into Operation: Follow the guidelines above and all relevant Installation and Maintenance Instructions  

 

supplied with the valve FRL or vacuum component to insure proper function of the system.

Pneumatic Products
Warnings

Catalog 0600P-10/USA

Safety Guide

Содержание "N" Series

Страница 1: ...m pneu n Basic Valve Functions M2 N Series Basic Features M3 Common Part Numbers M4 M5 Model Number Index M6 M7 Technical Information Pilot Supply M8 M9 Electrical Connections M10 Solenoid Characteris...

Страница 2: ...t restrict the inlet Note For 2 Way Normally Closed Exhaust Port is Plugged Single Solenoid 3 Way 2 Position NO NP Normal position Pressure at inlet port marked IN open to cylinder Exhaust port is blo...

Страница 3: ...3 8 Body 3 8 1 2 NPT 3 4 Body 1 2 3 4 1 NPT 1 1 4 Body 1 1 1 4 1 1 2 NPT BSPP G Threads Available Operating Pressure 30 to 250 PSI 0 to 1000 kPa Vacuum with External Pilot Features Continuous Duty Rat...

Страница 4: ...tandard Service Junction Box w Light 120VAC 3 8 3 4 Body Size 3 Way Normally Open In Cyl Ports Exh Port N375 39 045 53 3 8 1 2 N375 49 045 53 1 2 1 2 N375 59 045 53 1 2 3 4 N375 69 045 53 3 4 1 N375 7...

Страница 5: ...3 4 N374 61 091 3 4 1 N374 71 091 1 1 1 4 NPT Remote Pilot Port with Internal Pilot Return Single Remote Pilot Normally Closed 2 Way 2 Position 3 Way 2 Position Single Remote Pilot Normally Open 3 Wa...

Страница 6: ...Cyl 1 1 2 Exhaust BSPP S 1 1 2 Inlet Cyl 1 1 2 Exhaust NPT 9 1 1 2 Inlet Cyl 1 1 2 Exhaust BSPP T Not available with Valve Function 325 Note BSPP is to the ISO 228 Standard and requires an R BSPT male...

Страница 7: ...Options AC 60hz AC 50hz DC Standard Duty 49 24 5 6 53 120 110 5 6 8 9 Solenoid Type 0 Standard P Pilot Configuration 02 External Pilot Std Service 125 PSI 47 Internal Pilot Std Service 125 PSI Valve F...

Страница 8: ...PSI 3 8 Basic 3 4 Basic 25 PSI 35 200 35 200 50 PSI 45 200 40 200 75 PSI 55 200 50 200 100 PSI 65 200 65 200 150 PSI 80 200 80 200 250 PSI 110 200 110 200 External Pilot supply should be used when th...

Страница 9: ...n air reservoir is located close to the valve inlet as to not starve the valve of air pressure Basic Valve Size Inlet Port Size Exhaust Port Size Cv Inlet to Cylinder Cv Cylinder to Exhaust 3 8 3 Way...

Страница 10: ...2 SOLENOID COIL 4 PIN MICRO TOP COVER 1 2 3 4 5 SOLENOID COIL 5 Pin Male Single Solenoid Encl Option N Wiring Option F 4 Pin Male Single Solenoid Encl Option J Wiring Option F 3 Pin Male Single Soleno...

Страница 11: ...ontinuous Duty Pilot 3 8 3 4 Basic L Pilot Voltage Cycles Amps Inrush Amps Holding Resistance Ohms Watts Insulation Class 120 60VAC 29 18 122 12 B 110 50VAC 21 14 122 12 B 240 60VAC 18 12 610 12 B 24...

Страница 12: ...0 H142 01 Seal 11 K41RB72011 O Ring STD Service H249 69 O Ring Continuous Duty Item No Part Number Description 12 K272 004 Plunger Guide 13 K152 003 Override Assembly 14 K183 047 Cover Gasket 16 K183...

Страница 13: ...STD Service 7 K41RB72011 O Ring STD Service H249 69 O Ring Continuous Duty 10 K423 001 Top Seat K423 002 Top Seat Continuous Duty 11 K593 025 Coil 120V 60Hz 110V 50Hz K593 035 Coil 240V 60Hz 220V 50H...

Страница 14: ...42 Plunger 8 K423 020 Top Seat 1 8 Orifice K423 022 Top Seat 3 16 Orifice 9 H134 36 Seal 10 H142 02 Seal 11 H142 15 Seal 12 K322 004 Junction Box Kit 13 K183 012 Gasket Coil leads are 19 long Parts in...

Страница 15: ...9 24 K593097 51 48 K593254 53 115 K593108 58 230 K593111 Coils for L Pilot Operated Valves Coils for P Pilot Operated Valves Voltage Code Voltage Coil 60Hz 50Hz DC 19 Leads 72 Leads 40 12 K593007 41 4...

Страница 16: ...e valve Function Time delay to be used with external pressure return valve only Time delay modules provide precise consistent delay of valve shift They eliminate the need for electrical timers and rel...

Страница 17: ...uded in seal kit Key 3 8 Valve 3 4 Valve Description 1 1 2 Tap K053 075 Body N C 3 8 Tap K053 022 3 4 Tap K053 076 1 2 Tap K053 023 1 Tap K053 220 1A 3 4 Tap K053 077 Body N O 3 8 Tap K053 025 3 4 Tap...

Страница 18: ...72121 K41RB72221 O Ring Parts included in seal kit Key 3 8 Valve 3 4 Valve Description 1 1 2 Tap K053 067 Body N C 3 8 Tap K053 019 3 4 Tap K053 069 1 2 Tap K053 157 1 Tap K053 221 1A 3 4 Tap K053 065...

Страница 19: ...8 H178 17 Washer 9 H063 38 Stop Nut 10 K092 046 Bottom Cap N C 10A K103 061 Bottom Cap N O 11 K183 058 Gasket 12 K473 016 Spring 13 K012 003 Adapter 14 K41RB72143 O Ring Parts included in seal kit Nor...

Страница 20: ...34 136 K 3 44 87 N 2 31 59 P 10 45 265 Q 4 56 116 Key 1 1 4 Valve Description 5 K493 016 Stem 6 K313 028 Lower Piston 7 H137 28 Seal 8 H178 17 Washer 9 H063 38 Stop Nut 10 K092 046 Bottom Cap N C 10A...

Страница 21: ...3 018 K123 021 K123 024 Cover Parts included in seal kit Key 3 8 Valve 3 4 Valve 1 1 4 Valve Description 1 1 2 Tap K053 075 1 Tap K053 111 Body N O 3 8 Tap K053 022 3 4 Tap K053 076 1 1 4 Tap K053 112...

Страница 22: ...002 K313 028 Lower Piston Assy 7 H135 19 H136 76 H137 28 Seal 8 H178 11 H178 13 H178 17 Washer 2 9 H063 26 H063 32 H063 38 Stop Nut 2 10 K092 020 K092 034 K092 046 Bottom Cap Assy N C 10A K103 035 K1...

Страница 23: ...to change by Parker Hannifin Corporation and its subsidiaries at any time without notice Offer of Sale The items described in this document are hereby offered for sale by Parker Hannifin Corporation i...

Страница 24: ...alve FRL Vacuum component or accessory Assuring that all user s performance endurance maintenance safety and warning requirements are met and that the application presents no health or safety hazards...

Страница 25: ...mponents Air leakage Look and listen to see if there are any signs of visual damage to any of the components in the system Leakage is an indication of worn or damaged components Damaged or degraded co...

Страница 26: ...which is utilized in the manufacture of the items sold hereunder even if such apparatus has been specially converted or adapted for such manufacture and notwithstanding any charges paid by Buyer Unle...

Отзывы: