Encoder Specifications  

Description

 

Specification

 

Input Power 

5 VDC +/-10%  
Analog < 100mA,  Digital<200 mA depending on encoder 

Output 
(Incremental) 

Digital- Square wave differential line driver (EIA RS422A) 2 channels A and B in quadra-
ture (90

o

) phase shift. 

Analog– 2 channels V

and V

2

 differential sinusoids in quadrature 

Reference (Z 
Channel) 

Digital- Synchronized pulse, duration equal to one resolution bit.  Repeatability of position 
is unidirectional moving toward positive direction and is equal to table repeatability specifi-
cations. 
Analog– Differential pulse, bi-directional repeatability 

Maximum Speed 

Limited by table speed   

Limit and Home Sensor Specifications 

Description

 

Specification

 

Input Power 

NPN: +5 to 24 VDC +/- 5%, 25 mA 
PNP: +5 to 24 VDC +/- 5%, 25 mA plus up to 50mA per output 

Output 

NPN - Normally Closed Current Sinking Limits, Normally Open Current Sinking Home 
PNP - Normally Closed Current Sourcing Limits, Normally Open Current Sourcing Home 
NPN - +5 to +24 VDC All outputs Sink a max. of 50mA each 
PNP - +5 to +24 VDC All outputs Source a max. of 50mA each 

Repeatability 

Home Sensor: +/- 5 

m (unidirectional) plus repeatability of the positioner 

ViX Drive Specifications 

Refer to Specifications provided in ViX Manual, available at www.Compumotor.com. 

Digital Outputs 

Interface 

Function 

Signal 

Pin 

Power 

5 V 

7,8 

0 V 

2,9 

Incremental 

A+ 

14 

A- 

B+ 

13 

B- 

Reference mark 

Z+ 

12 

Z- 

Limits 

11 

10 

Set-up 

Alarm 

E- 

Shield 

Inner 

Outer 

Case 

Analog Outputs 

Readhead  Interface 

Function 

Signal 

Color 

Pin 

Power 

5 V 

Brown 

4,5 

0 V 

White 

12, 13 

Incre-

mental 

Cosine 

V₁+ 

Red 

V₁- 

Blue 

Sine 

V₂+ 

Yellow 

10 

V₂- 

Green 

Reference mark 

V₀+ 

Violet 

V₀- 

Grey 

11 

Limits 

V

Pink 

V

Black 

Set-up 

Vₓ 

Clear 

Remote CAL 

CAL 

Orange 

14 

Shield 

Inner 

Green/Yellow 

Outer 

Outer screen 

Case 

* Inner Shield is connected to 0V inside the Ti interface 

Содержание MX45S Series

Страница 1: ...Manual No 102 3619 01 Rev 2 MX45S Series Product Manual Effective March 5 2013 Supersedes Electromechanical Positioning Systems Automation www runcheng net www runcheng net...

Страница 2: ...ety and warning requirements of the application are met The products described herein including without limitation product features specifications designs availability and pric ing are subject to chan...

Страница 3: ......

Страница 4: ...MX45S Series Product Manual 4 Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania Revision Notes Revision 1 Original Document...

Страница 5: ...ect the unit for any evidence of shipping damage Report any damage immediately to your local authorized distributor Please save the shipping container for damage inspection or future transportation In...

Страница 6: ......

Страница 7: ......

Страница 8: ...MX45S Series Product Manual 8 Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania Assembly Diagram...

Страница 9: ......

Страница 10: ...MX45S Series Product Manual 10 Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania 83 6 MX45S Dimensions mm in...

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...lus up to 50mA per output Output NPN Normally Closed Current Sinking Limits Normally Open Current Sinking Home PNP Normally Closed Current Sourcing Limits Normally Open Current Sourcing Home NPN 5 to...

Страница 17: ...2399 length Rotary Encoder Cable 9pin DSUB ER12 ER13 ER22 ER23 Pin Function Wire Color 1 5V Brown 2 A Green 3 A Yellow 4 B Blue 5 B Red 9 GND White SHLD SHLD SHLD 006 2409 length Motor Extension Cabl...

Страница 18: ...mounting surface cannot meet these specifications a separate rigid mounting plate meeting these specifications should be used to mount to the main structure If mounting conditions require that the tab...

Страница 19: ...lation See the drawing below for installation of magnets For more information on the magnets and instal lation see Renishaw installation guide M 9653 9154 01 A Optional NEMA 8 Motor Following are the...

Страница 20: ......

Страница 21: ......

Страница 22: ...and tinned and ready for installation into the screw terminals on the ViX drive For wire color codes and pin outs see tables in electrical section of manual Recommended bend radius for these cables is...

Страница 23: ...celerations Available Motor Force This is the primary factor that reduces acceleration This is simply the amount of motor force avail able to produce acceleration The larger the inertial and or fricti...

Страница 24: ......

Страница 25: ...buttery Maintenance Frequency Cross roller bearings and drive screws are lubricated at our facility prior to shipment For lubrica tion inspection and supply intervals following shipment apply grease o...

Страница 26: ...stablishment of a two digit numeric rating verify the extent of protection provided against access to hazardous parts against ingress of solid foreign objects and against the ingress of water First Nu...

Страница 27: ......

Страница 28: ......

Страница 29: ......

Страница 30: ...www runcheng net www runcheng net...

Отзывы: