Parker Pro Display 12 Instruction Book
53/54
*) NOTICE: Recommended operating voltage range is 9V…36V, even the product is
tested with this broader voltage range.
Table 36: Electromagnetic compatibility
Test Description
Specification
Test level/ Rating
Conducted transient
emission
ISO 7637-2
•
III
Radiated RF emission
CISPR 25 ed3.0
•
III
Radiated RF susceptibility
ISO 11452-1, ISO 11452-2
•
IV
Immunity to low-frequency
magnetic fields
ISO 11452-8
•
IV
Conducted RF emission
CISPR 25 ed3.0
•
III
Conducted susceptibility
ISO 11452-1, ISO 11452-4
•
IV
Transient - inductive load
switching, inductance,
coupling, cranking, load
dump
ISO 7637-2
•
Pulse 1: III (12 & 24V)
•
Pulse 2a: III (12 & 24V)
•
Pulse 2b: IV (12 & 24V)
•
Pulse 3a: III (12 & 24V)
•
Pulse 3b: III (12 & 24V)
•
Pulse 4: III / IV (12 & 24V)
•
Pulse 5a: III, UA: 27V; Us:
123V;
Transient, signal lines, fast
ISO 7637-3
•
IV