Table 35: Environmental Protection – Electrical
Test Description
Specification
Test level/ Rating
Operation voltage *
ISO 16750-2
•
6V…16V (12V systems)
•
10V…32V (24V systems)
Overvoltage
ISO 16750-2
•
Test level: 48V
•
Test time: 1 min / 5 min
Superimposed alternating voltage
ISO 16750-2
•
Test voltages Umax: 16V
and 32V
•
Test severity: 2 (Upp: 4V)
•
Test frequency: 50 Hz –
20 kHz
•
Frequency sweep:
Triangular, linear
•
Sweep duration: 120 s
•
Number of sweeps: 5
Reversed voltage
ISO 16750-2
•
Test level UA: -36V (24V
system).
•
Test level UA: -24V (12V
system).
•
Duration: 5 min.
Slow decrease and increase
of supply voltage
ISO 16750-2
•
Supply voltage range: 8 to
36V.
•
Decrease the supply
voltage from Umax to 0V
and then increase it from
0V to Umax
•
Change rate: 0,5 ±0,1
V/min.
Momentary drop on supply voltage ISO 16750-2
•
Supply voltage Umin: 8V
•
Voltage drop to 4,5V for
100 ms
•
Rise/fall time: 10 ms
Reset behaviour at voltage drop
ISO 16750-2
Line interruption (single & multiple
line interruption)
ISO 16750-2
•
Interruption time: 10 s
•
Oper.voltage UA: 28V.
Short circuit protection
(signal & load circuits)
ISO 16750-2
•
60 s / 5 min
Power supply with and without
battery
Parker
Immunity to micro power cuts
Parker
•
Unom: 13,5V and 27V
•
Transit.app: 10
μ
s
•
Cut durations: 100, 200
and 400 µs
•
Test duration: 5 pulses for
each level
•
Pulse period > 1 s