background image

 2

Overview of relevant documentation

1     Introduction

Instruction book, IQAN- XT2

Overview of relevant documentation

The following publications are relevant for users of this product.

The main documentation contains information that is not found elsewhere. 

The additional documentation contains product information in a compact format, for 
details on the information found in those documents, consult this manual.

The IQAN-XT2 module documentation system.

IQANde

s

ign/

IQANdevelop 

U

s

er M

a

n

ua

l

IQAN-XT2 In

s

tr

u

ction Book

HY

33

-

83

1

3

-IB

(thi

s

 

b

ook)

IQAN-XT2 

C

a

t

a

log

u

e D

a

t

as

heet

HY

33

-

83

1

3

IQAN-XT2

In

s

t

a

ll

a

tion 

S

heet

HY

33

-

83

1

3

-I

S

IQAN-XT2

Electric

a

S

chem

a

tic

HY

33

-

83

1

3

-E

S

Compact

Documentation

Main

Documentation

Содержание IQAN-XT2

Страница 1: ...IQAN XT2 Instruction book Publ no HY33 8313 IB UK Edition 2012 11 06...

Страница 2: ...ing 7 Mounting the module 7 6 Installation 8 Connector C1 8 Supply voltage 9 IQAN XT2 addressing terminating 10 CAN connection 11 Reference voltage VREF 11 Voltage inputs 12 Frequency inputs 15 Curren...

Страница 3: ...e is common to the term hazardous situation that a person is exposed to a hazard As a way of pointing out important information for the machine designer that in some way relates to safety This include...

Страница 4: ...ere The additional documentation contains product information in a compact format for details on the information found in those documents consult this manual The IQAN XT2 module documentation system I...

Страница 5: ...stem must be disconnected from other equipment The negative cable must always be disconnected from the battery before disconnecting the positive cable The ground wire of the welder shall be positioned...

Страница 6: ...ied out by trained personnel who are well acquainted with the control system the machine and its safety regulations Before you start Read section Start up on page 21 Additional information for service...

Страница 7: ...lves The module also has six 6 digital outputs for on off valves which can be configured as either six 6 individual or three 3 double PWM outputs Pulse Width Modulation for non regulated control of pr...

Страница 8: ...er will use zero or an application defined error value for the module inputs and the module outputs will be off The error will be indicated both on the master module and with a blink code on the unit...

Страница 9: ...o external heat e g from the engine or heater is transferred to the module Locate the module to protect it from high pressure washing or similar Locate the module so that the cable connector is facing...

Страница 10: ...p no 963531 1 MT Amp no 828922 JPT IQAN crimping tool references Blue handle pos B use blue extraction tool Red handle pos B use yellow extraction tool IQAN tool kit Parker no 5031061 Pos Signal name...

Страница 11: ...module by using a fuse Requisite fuse level should be 20 A fast F Connecting the emergency stop and voltage supply NOTICE Do not use the chassis as the negative terminal Supplying a high current draw...

Страница 12: ...communication through the CAN bus the CAN bus must be terminated Because the master module always is located at the beginning of the bus the master is provided with an internal termination You will o...

Страница 13: ...e the reference voltages VREF and VREF_EGAS The standard reference voltage will feed different kinds of sensors The EGAS reference voltage is intended to supply an electronic throttle device VREF posi...

Страница 14: ...ve terminal of the sensor must not be connected to the chassis Maximum load for VREF position see Appendix A on page 23 Connecting other 3 wire sensors The same type of connection shown for potentiome...

Страница 15: ...l Please check the technical data for your specific temperature sensor EXAMPLE Connect the negative terminal of the temperature sensor to VREF position 13 and the signal to VIN A position 21 The pull...

Страница 16: ...ion see Appendix A on page 23 It is recommended to connect system voltage BAT to the voltage input through a switch in order to reserve 5Vdc VREF for sensors and potentiometers EXAMPLE Connect the pos...

Страница 17: ...ed to the FIN position If the current consumption for the sensor exeeds the maximum load for the VREF the sensor could be connected to the BAT positions NOTICE The negative terminal of the sensor must...

Страница 18: ...dither frequency amplitude set up can be supplied by Parker Hannifin Corporation in order to obtain an optimized valve hysteresis Both frequency and amplitudes will then be set in IQANdevelop Connect...

Страница 19: ...hin IQANdevelop The Soft start function Peak and Hold The Peak and Hold feature makes it possible to decrease the voltage to the valve solenoid Shortly after a valve has been activated the voltage can...

Страница 20: ...tput against high voltage transients For example Use the diode 1N5408 3A 1000V Depending on the load other clamping diodes might be used instead EXAMPLE Connect the on off valve to the digital output...

Страница 21: ...t be placed between the output and ground as close to the load as possible to protect the output against high voltages transients For example Use the diode 1N5408 3A 1000V Depending on the load other...

Страница 22: ...its travel The EGAS actuator must be aligned parallel to the diesel engine injector lever Do not exceed maximum torque of the EGAS actuator see the EGAS manufacturer s datasheet for torque specificati...

Страница 23: ...ernatively the emergency stop may also shut off the diesel engine or a dump valve and with that depressurize the hydraulic system Prepare for system start WARNING Make sure no one is in dangerous prox...

Страница 24: ...the nature of the error that has occurred The location of the LED indicators on the IQAN XT2 module The green LED indicates power on The yellow red LED will be blinking red when an error has been det...

Страница 25: ...ental ratings Parameter Remark EMI ISO 14982 1998 Radiated emission EN 55025 2003 Conducted emission ISO 11452 2 1995 Radiated Susceptilbility ISO 11452 4 2001 Conducted Susceptibility ISO 7637 2 2004...

Страница 26: ...elay TBD ms Power to activated output Dither frequency DF 25 150 Hz Sample rate local I O 20 Hz Dependent of the CAN sample time exception FIN channels CAN message response time TBD ms Output voltage...

Страница 27: ...mA Load 3 5 W Voltage drop VBAT VCOUT load IL 0 5A load IL 2A 0 2 0 8 V Off State output current TBD mA Relative accuracyb 30 mA PVC25 12V PVC25 24V Deviation from Meanc TBD mA PVC25 12V PVC25 24V Te...

Страница 28: ...up A or B C or D E or F 4 A The PWMOUT s are divided into three groups Signal range TBD TBD MR Voltage drop VBAT VPWMOUT load IL 0 5A load IL 2A 0 2 0 8 V Off State output current TBD mA Short Circuit...

Страница 29: ...off or at least shut down the outputs to increase safety WARNING Don t use the machine if an error message or error code is activated The following sections will present what measures to take for diff...

Страница 30: ...on Error code Action IQAN XT2 Comment CAN bus off Error 3 All outputs shut off Check CAN bus ADDR H 4 9 V Error 5 Check voltage ADDR H ADDR H 5 1 V Error 5 Check voltage ADDR H ADDR L 0 5 V Error 5 Du...

Страница 31: ...t return low Error 1 Active output shuts off Check load COUT Current return high Error 1 In current check activated Active output shuts off Check load DOUT Overload Error 1 Active output shuts off Che...

Страница 32: ...30 Dimensioning of the IQAN XT2 module Appendix C Instruction book IQAN XT2 Appendix C Dimensioning of the IQAN XT2 module 7 mm M6 x2 142 164 60 32 67 52 75 7 mm M6 x2 142 164 60 32 67 52 75 Unit mm...

Страница 33: ...e without notice Parker Hannifin Electronic Controls Division SE 435 35 M lnlycke Sweden Tel 46 31 750 44 00 Fax 46 31 750 44 21 www parker com Parker Hannifin Electronic Controls Division 1651 N Main...