background image

 5

IQAN-XA2

3     Product description

Instruction book, IQAN- XA2

3

Product description

IQAN-XA2

The IQAN-XA2 is a flexible expansion module designed for controlling hydraulic 
systems in vehicles and machinery, using 12/24 Vdc power supply.

The IQAN-XA2 module.

I/O overview

Inputs

The IQAN-XA2 module has eight (8) 

voltage inputs 

VIN-A thru VIN-H for connection 

of 0-5 Vdc signals. The inputs VIN-E thru VIN-H are multi-purpose and for flexibility 
may be configured in other ways. The two input pins VIN-E and VIN-G can be 
configured as 

frequency inputs 

for measuring frequency. The group of four pins VIN-E 

thru VIN-H can be configured as 

quadrature 

or

 directional inputs

 for measuring 

directional frequency. 

Voltage inputs, frequency inputs, quadrature inputs 

and 

directional inputs 

share positions, see below.

(

8

) Voltage inputs VIN-A, VIN-B, VIN-C, VIN-D.....VIN-H

or

(6) Voltage inputs VIN-A thru VIN-D,VIN-F and VIN-H. 
(2) Frequency inputs FIN-A and FIN-B use positions VIN-E and VIN-G.

or

(4) Voltage inputs VIN-A thru VIN-D. (2) Quadrature or Directional inputs 
DFIN-A+/DFIN-A- and DFIN-B+/DFIN-B- use positions VIN-E thru VIN-H.

or

(

8

) Digital inputs DIN-A, DIN-B.....DIN-H use positions VIN-A thru VIN-H.

+BAT

ADDR-H
ADDR-L
CAN-H
CAN-L

PORT 1

PORT 2

-BAT

+VREF

-VREF

PORT 0

XA2

Содержание IQAN-XA2

Страница 1: ...IQAN XA2 Instruction book Publ no HY33 8385 IB UK Edition 2016 12 16...

Страница 2: ...essing terminating 12 Reference voltage VREF 13 Voltage inputs 14 Digital inputs 17 Frequency inputs 19 Quadrature and directional frequency inputs 20 Proportional outputs 21 Connecting loads to propo...

Страница 3: ...is common to the term hazardous situation that a person is exposed to a hazard As a way of pointing out important information for the machine designer that in some way relates to safety This includes...

Страница 4: ...he additional documentation contains product information in a compact format for details on the information found in those documents consult this manual The IQAN module documentation system Compact Do...

Страница 5: ...ctions on the system must be disconnected from other equipment The negative cable must always be disconnected from the battery before disconnecting the positive cable The ground wire of the welder sha...

Страница 6: ...ics may only be carried out by trained personnel who are well acquainted with the control system the machine and its safety regulations Before you start Read section Start up Additional information fo...

Страница 7: ...ured as frequency inputs for measuring frequency The group of four pins VIN E thru VIN H can be configured as quadrature or directional inputs for measuring directional frequency Voltage inputs freque...

Страница 8: ...flexibility these outputs may also be configured as up to six 6 on off outputs and up to twelve 12 on off intputs The proportional outputs on off outputs and on off inputs share positions see below I...

Страница 9: ...lication defined error value for the module inputs and the module outputs will be off The error will be presented on the master display module if there is one and with a related blink code on the IQAN...

Страница 10: ...ferred to the module Locate the module to protect it from high pressure washing or similar Locate the module so that the cable connector is facing down Locate the module so that the LEDs are visible N...

Страница 11: ...raction tool IQAN tool kit Parker no 5031061 Logical Symbol Pin No I nput or O utput Function description and or Signal name s BAT 28 Power supply positive BAT 15 Power supply negative ground VREF 42...

Страница 12: ...2 8 P2 9 P2 10 P2 11 P2 12 P2 13 P2 14 P2 15 P2 16 P2 17 2 16 30 3 17 31 4 18 32 5 19 33 6 20 34 7 21 35 O O I O I O O I O I O O I O I O O I O I O O I O I O O I O I P2 is an 18 pin input output port w...

Страница 13: ...r should be as close to the battery as possible for safety IQAN expansion modules do not have RTC WARNING Risk of injury To reduce the risk for uncontrolled supply of an IQAN master module i e a short...

Страница 14: ...t will be terminated internally to be the Bus master and will have no special configuration When an IQAN expansion module is located at the end of the CAN bus then you would use an ID tag having a com...

Страница 15: ...ors and potentiometers VREF positions NOTICE It is strongly recommended to use the module s VREF and VREF to all sensors and potentiometers that are connected to the module inputs This will reduce bad...

Страница 16: ...on NOTICE The negative terminal of the sensor must not be connected to the chassis Maximum load for VREF position see Appendix A Connecting other 3 wire sensors The same type of connection shown for p...

Страница 17: ...d be connected to VREF and VIN DIN respectively for 5V signal The current consumption for the input is negligible NOTICE Maximum load for VREF position see Appendix A EXAMPLE Connect the negative term...

Страница 18: ...ed to connect system voltage BAT to the input through a switch in order to reserve 5Vdc VREF for sensors and potentiometers EXAMPLE Connect the positive and negative terminals of the switch to supply...

Страница 19: ...ing switches to the digital inputs DIN that share pins with CRET extra precautions should be taken WARNING The DIN that share pins with the CRET positions of the proportional outputs have a possibilit...

Страница 20: ...4 Vdc systems The DIN signal will not be detected by the module Remember that these flexible I O pins must be configured in pairs of the same type EXAMPLE Connect the supply of the switch to BAT throu...

Страница 21: ...e terminal to the VREF respectively The sensor signal is connected to the FIN position If the current consumption for the sensor exeeds the maximum load for the VREF the sensor could be connected to t...

Страница 22: ...VREF and the negative terminal to the VREF respectively The sensor s channel A is connected to DFIN A and channel B to DFIN A positions Directional frequency sensor The positive terminal of the direc...

Страница 23: ...an be changed using IQAN software For the possible frequencies see Appendix A Connecting loads to proportional COUT outputs Connecting a load e g one proportional valve section to the current mode out...

Страница 24: ...the diode between the PWMOUT and PWMRET or the PWMOUT and ground as close to the load as possible This protects the output against high voltage transients For example use diode 1N5408 3A 1000V Dependi...

Страница 25: ...d as close to the load as possible This protects the output against high voltage transients For example use diode 1N5408 3A 1000V Depending on the load other clamping diodes might be used instead EXAM...

Страница 26: ...a tively the emergency stop may also shut off the diesel engine or a dump valve and with that depressurize the hydraulic system Prepare for system start WARNING Make sure no one is in dangerous proxim...

Страница 27: ...dicate error status through the red blinking LED This gives an immediate diagnosis as to the nature of the error that has occurred The location of the LED indicators on the IQAN module The green LED i...

Страница 28: ...sient susceptibility 30 1000 MHz 0 15 108 MHz Class 1 200 2000 MHz 1 kHz 80 AM 100V m 1 200 MHz 1 kHz 80 AM 150mA Pulse 1 2 2b 3a 3b 4 Level 3 Pulse 5 Level 1 ESD ISO 10605 2001 ESD operation ISO 1060...

Страница 29: ...DIN 20 configuration may reduce number Logic levels low high 1 V 4 V Input hysteresis DIN A to DIN H DIN I to DIN T typ 1 0 V typ 0 5 V Input impedance DIN A to DIN H DIN I to DIN T 62 kohm pull down...

Страница 30: ...COUT saturation 95 100 Hz dither Absolute accuracy 2 15 mA Dither frequency FDITH see table Supply rejection 2 mA VBAT change 9 to 18 V or 18 to 32 V Load rejection 2 mA load change 50 Maximum load VB...

Страница 31: ...inductance VBAT 14 V single pulse VBAT 28V single pulse PWM incl Softstart Softstop 14 Ohm 366 mH 9 3 ohm 126 mH 7 ohm 50 mH 28 Ohm 334 mH 19 ohm 114 mH 14 ohm 46 mH external clamping diode is mandato...

Страница 32: ...put by the module for proportional valve control Frequency Hz entered in appl Frequency Hz output by module Frequency Hz entered in appl Frequency Hz output by module 25 25 50 52 50 26 26 53 55 53 27...

Страница 33: ...location of the LED indicators on the IQAN XA2 module WARNING Don t use the machine if an error message or error code is activated The following sections will present what measures to take for differ...

Страница 34: ...32 Dimensioning of the IQAN module Appendix C Instruction book IQAN Appendix C Dimensioning of the IQAN module 7 mm M6 x2 142 164 60 32 67 52 75 Unit mm...

Страница 35: ...d error value a 3 VREF Short circuit to VREF VREF error VIN out of range will create a VIN error VIN Predefined error value a 4 VREF Short circuited to BAT VREF error VIN out of range will create a VI...

Страница 36: ...IN error VIN Predefined error valuea 3 VIN Short circuited to BAT VIN out of range will create a VIN error VIN Predefined error valuea Failure mode Effect 1 DIN Open No effect on module not detected 2...

Страница 37: ...BAT COUT error output turned off 7 COUT Short circuit to BAT COUT error output turned offb 8 RET active Short circuit to BAT COUT error output turned offb 9 RET active Short circuit to BAT COUT error...

Страница 38: ...influence function 6 H side Short circuit to BAT PWMOUT error output turned off 7 H side Short circuit to BAT PWMOUT error output turned offb 8 L side active Short circuit to BAT PWMOUT error output t...

Страница 39: ...without notice Parker Hannifin Mobile Hydraulic Systems Europe SE 435 35 M lnlycke Sweden Tel 46 31 750 44 00 Fax 46 31 750 44 21 www parker com Parker Hannifin Electronic Controls Division 1651 N Ma...

Отзывы: