![Parker IQAN-XA2 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/parker/iqan-xa2/iqan-xa2_instruction-book_4039136038.webp)
3
6
Failure Modes
Appendix D
Instruction book, IQAN-XA2
Failure modes in PWM mode
Table below presents failure modes and effects on I/O.
Failure mode
Effect
a
a.
Turning off outputs are controlled by CAN master and therefore delayed by maximum
2 bus cycles. If local error handling is enabled the output will turn off locally without
delay.
1
H-side Open
PWMOUT error, output turned off
2
L-side (active) Open
PWMOUT error, output turned off
3
L-side (passive) Open
Not detected, will not influence function
4 H-side
S
hort-circuit to L-side
(active)
PWMOUT error, output turned off
b
b.
Turned off by integrated protection functions in IC.
5 H-side
S
hort-circuit to L-side
(passive)
Not detected, will not influence function
6 H-side
S
hort-circuit to +BAT
PWMOUT error, output turned off
7 H-side
S
hort-circuit to - BAT
PWMOUT error, output turned off
b
8
L-side
(active)
S
hort-circuit to
+BAT
PWMOUT error, output turned off
b
9 L-side
(active)
S
hort-circuit to
- BAT
Not detected, will not influence function
10 L-side
(passive)
S
hort-circuit to
+BAT
Not detected, will not influence function
11 L-side
(passive)
S
hort-circuit to
- BAT
Not detected, + and - direction activated without
movement as result.
12 H-side
S
hort-circuit to 2:nd
L-side (active)
PWMOUT error, output turned off
b
1
3
H-side
S
hort-circuit to 2:nd
L-side (passive)
Not detected, will not influence function
14 L-side
S
hort-circuit to 2:nd L-side
(active)
Not detected, will not influence function
15 L-side
S
hort-circuit to 2:nd L-side
(passive)
Not detected, will not influence function
16
Insufficient Voltage
Not detected, lower max speed limit on function