ELECTRICAL INSTALLATION
42
IPA Hardware Installation Guide
Output (Motor) Power
Output Power Ratings
Continuous and peak output power ratings for all IPA models are listed in the following table.
Output Power Ratings
Model
Continuous Peak Max
Cont. Max Peak
Current (RMS) Current (RMS) Shaft Power (Watts) Shaft Power (Watts)
IPA04-HC
3.00
9.00
400
1200
IPA15-HC
6.30
18.90
1500
4500
Output (Motor) Power Connections
The following figure shows how to connect the motor cable to the Output Power connector.
Figure 13. -
Output Power Connection
Current Parker motor cables are marked with white numbers (1, 2, or 3) to indicate the phase. Connect Motor
Phase 1 to U, 2 to V, and 3 to W, and Motor Safety Earth to the Protective Earth ground connector.
Warning:
You must connect the Motor Safety Earth conductor terminal,
marked with the earth symbol , to the motor cable’s motor-
safety-earth wire green/yellow).
The following table contains wiring information for making connections with various Parker Hannifin motors.
Wiring to Parker Motors
Phase
Hi-Flex/ PS/Gemini
Legacy Parker Hannifin
U
1
Red/Yellow
V
2
White/Yellow
W
3
Black/Yellow
Green/Yellow
Green/Yellow
Содержание IPA Series
Страница 2: ......
Страница 14: ...INTRODUCTION 14 IPA Hardware Installation Guide CHAPTER 1 Introduction...
Страница 18: ...MECHANICAL INSTALLATION 18 IPA Hardware Installation Guide CHAPTER 2 Mechanical Installation...
Страница 24: ...ELECTRICAL INSTALLATION 24 IPA Hardware Installation Guide CHAPTER 3 Electrical Installation...
Страница 54: ...TROUBLESHOOTING 54 IPA Hardware Installation Guide CHAPTER 4 Communications...
Страница 63: ...TROUBLESHOOTING IPA Hardware Installation Guide 63 CHAPTER 5 Troubleshooting...
Страница 77: ......
Страница 78: ...TORQUE ENABLE SAFETY CIRCUITRY 78 IPA Hardware Installation Guide CHAPTER 6 Torque Enable Safety Circuitry...
Страница 84: ...ADDITIONAL SPECIFICATIONS 84 IPA Hardware Installation Guide CHAPTER 7 Additional Specifications...
Страница 90: ...REGULATORY COMPLIANCE UL AND CE 90 IPA Hardware Installation Guide CHAPTER 8 Regulatory Compliance UL and CE...
Страница 100: ...REGULATORY COMPLIANCE UL AND CE 100 IPA Hardware Installation Guide...
Страница 101: ......
Страница 102: ...APPENDIX A 102 IPA Hardware Installation Guide APPENDIX A VM25 Expansion Module...
Страница 104: ...APPENDIX B 104 IPA Hardware Installation Guide APPENDIX B IPA with IForce or Ripped Linear Servos...
Страница 114: ...APPENDIX C 114 IPA Hardware Installation Guide APPENDIX C IPA with Parker Mechanics...
Страница 124: ...APPENDIX C 124 IPA Hardware Installation Guide Applies to the following Parker Stages 402 403XE H3L2 HD085 125 185 LH2...