Mounting
HLR Mounting Instruction
34
192-510201N1 HLR 2019-04
Place the OSP-E20BV z-axis on the mounting plate and fasten it with the
supplied screws (see Figure 8: Pos. 6) and the required tightening torque (please
refer to Table 8).
HLR080
Tightening torque of mounting plates (Figure 8, Pos.4)
Screw type [ISO 4762]
-
M6x30 – A2-70
Tightening torque
[Nm]
8.8
Tightening torque of mounting plates (Figure 8, Pos.5)
Screw type [ISO 4762]
-
M5x20 – A2-70
Tightening torque
[Nm]
5.0
Tightening torque OSP-E20BV (Figure 8, Pos.6)
Screw type [ISO 4762]
-
M6x20 – A2-70
Tightening torque
[Nm]
6.4
Table 8: Tightening torques of mounting plates for OSAP 20-7
3.7
Assembly of accessories
In this chapter you can read about:
Sensors ........................................................................................................................... 34
External end stops ........................................................................................................... 36
3.7.1.
Sensors
All HLR linear actuators have a permanent magnet integrated in the carriage on
both sides of the support profile. It activates the sensors which are mounted in the
special mounting grooves on the support profile of the cylinder. For sensor
recommended please refer to the HLR catalogue.
Please observe the Operating Instructions of the manufacturer when
commissioning the sensors.
Sensor mounting
Remove the groove cover strips (Figure 9, Pos. 1) from the sensor groove (only
for HLR080) of the support profile.
Insert the sensor into the sensor groove for HLR080 (Figure 9, Pos. 1) and into
the T-slot (Figure 9), Pos.2) for HLR070 and push the sensor to the desired
position (position of the permanent magnet in the carriage profile (see Figure 9).
The position of the permanent magnet is not visible from the outside. Connect the
sensor on the power supply according to the operating instructions and move it in
the support profile along the carriage until the sensor is damped. This allows you
to determine on which side of the carriage the permanent magnet is located.
Tighten the fixing screws on the limit switches slightly and lead the cable along
the profile groove.
You can use the formerly removed protective covers (for HLR080 only) in order to
fix the sensor cables. Please cut the covers to the desired length. A pair of
scissors may be used. Insert the cover strips over the sensor cable in the groove
again. Insert the cables into the grooves of the plastic covers and push the cover
into the groove together with the cable.
Connect the sensors to the controller according to the description in the supplier’s
manual.
Содержание HLR Series
Страница 6: ...Introduction HLR Mounting Instruction 6 192 510201N1 HLR 2019 04 1 3 Mounting explanation...
Страница 14: ...Device description HLR Mounting Instruction 14 192 510201N1 HLR 2019 04...
Страница 15: ...Parker EME Conditions of utilization 192 510201N1 HLR 2019 04 15...
Страница 16: ...Device description HLR Mounting Instruction 16 192 510201N1 HLR 2019 04 2 1 Technical data...
Страница 17: ...Parker EME Dimensions 192 510201N1 HLR 2019 04 17 2 2 Dimensions...
Страница 18: ...Device description HLR Mounting Instruction 18 192 510201N1 HLR 2019 04...
Страница 19: ...Parker EME Dimensions 192 510201N1 HLR 2019 04 19...
Страница 54: ...Index HLR Mounting Instruction 54 192 510201N1 HLR 2019 04...
Страница 55: ...Parker EME Spare and Wear Parts 192 510201N1 HLR 2019 04 55...
Страница 56: ...Index HLR Mounting Instruction 56 192 510201N1 HLR 2019 04...