4.
COMMISSIONING, USE AND MAINTENANCE
4.1. Reception, handling, storage
4.1.1. Equipment delivery
All the GVM motors are strictly controlled during manufacturing, prior to shipping.
Upon receipt it, it is necessary to verify the motor condition and confirm it has not been
damaged during transit. Remove it carefully from its packaging. Verify that the data written
on the label are the same as the ones on the acknowledgement of order, and that all
documents or necessary accessories for user are present in the packaging.
Warning : In case of damaged material during the transport, the recipient
must
immediately
make representations to the carrier through a
registered mail within 24 h.
4.1.2. Handling
The GVM motors are equipped with threaded holes on its housing for handling.
DANGER: Only use the threaded holes the GVM motors are equipped
with for handling operations. Never use cables, connectors, input/output of
cooling circuit, or any other inappropriate lifting device.
DANGER: Choose the correct slings for the motor weight. The two slings
must be the same length and a minimum angle of 50° has to be
respected between the motor axis and the slings.
50°min
i
50°min
i
Содержание GVM Series
Страница 1: ...1 18 06 08 PVD3668_GB_GVM_June_2018 Global Vehicle Motors GVM Series Technical Manual PVD 3668_GB...
Страница 2: ...2 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 16: ...16 18 06 08 PVD3668_GB_GVM_June_2018 Consult us for more demanding applications...
Страница 28: ...28 18 06 08 PVD3668_GB_GVM_June_2018 GVM142 050 in Motor operation mode GVM142 050 in Generator operation mode...
Страница 29: ...29 18 06 08 PVD3668_GB_GVM_June_2018 GVM142 075 in Motor operation mode GVM142 075 in Generator operation mode...
Страница 30: ...30 18 06 08 PVD3668_GB_GVM_June_2018 GVM142 100 in Motor operation mode GVM142 100 in Generator operation mode...
Страница 32: ...32 18 06 08 PVD3668_GB_GVM_June_2018 GVM210 100 in Generator operation mode GVM210 150 in Motor operation mode...
Страница 33: ...33 18 06 08 PVD3668_GB_GVM_June_2018 GVM210 150 in Generator operation mode...
Страница 34: ...34 18 06 08 PVD3668_GB_GVM_June_2018 GVM210 200 in Motor operation mode GVM210 200 in Generator operation mode...
Страница 35: ...35 18 06 08 PVD3668_GB_GVM_June_2018 GVM210 300 in Motor operation mode GVM210 300 in Generator operation mode...
Страница 36: ...36 18 06 08 PVD3668_GB_GVM_June_2018 GVM210 400 in Motor operation mode GVM210 400 in Generator operation mode...
Страница 39: ...39 18 06 08 PVD3668_GB_GVM_June_2018 3 3 Dimension drawings 3 3 1 GVM142 outline drawings...
Страница 40: ...40 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 41: ...41 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 42: ...42 18 06 08 PVD3668_GB_GVM_June_2018 3 3 2 GVM210 outline drawings...
Страница 43: ...43 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 44: ...44 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 45: ...45 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 46: ...46 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 47: ...47 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 53: ...53 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 55: ...55 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 60: ...60 18 06 08 PVD3668_GB_GVM_June_2018 With Oil with a 46 cSt viscosity 40 C input at 65 C...