- 74
–
18-06-08 PVD3668_GB_GVM_June_2018
3.9. Feedback system
3.9.1. Resolver
A resolver determines the rotor position.
Its signals are processed by the drive in order to control the stator currents, the speed and
the position.
Resolver 2 poles transformation ratio = 0.5
– code A
GVM142
GVM210
Parker part number
220005P1002
220005P1003
Electrical specification
Values @ 8 kHz
Polarity
2 poles
Input voltage
7 Vrms
Input current
86mA maximum
56mA maximum
Zero voltage
20mV maximum
Encoder accuracy
± 10’ maxi
Ratio
0,5 ± 5 %
Output impedance
(primary in short circuit
whatever the position of
the rotor)
Typical 100 + 240j Ω
Typical 95 + 180j Ω
Dielectric rigidity
(50
– 60 Hz)
500 V
– 1 min
Insulation resistance
≥ 100MΩ
Rotor inertia
~30 g.cm²
~123 g.cm²
Operating temperature
range
-55 to +155 °C
Resolver connector
PIN
Signal
A
Ref Sin (-) S2
B
Sin (+) S4
J
Ref (+) R1
K
Ref (-) Ground R2
E
Ref Cos (-) S1
F
Cos (+) S3
C
PTC Therm Disconnect (+)
D
PTC Therm Disconnect (-)
G
KTY Winding Therm (+)
H
KTY Winding Therm (-)
L,M,N,P,R,S,T,U,V
Not Connected
In this case, Parker can provide Resolver Sensor cables, to be placed between the motor
and the drive, with standard lengths of 1, 2, 3 or 4 meters ; its part number is built as follows
“CBFRE0H0-SRX-000-00x0-00” where “x” is the length in meter.
Содержание GVM Series
Страница 1: ...1 18 06 08 PVD3668_GB_GVM_June_2018 Global Vehicle Motors GVM Series Technical Manual PVD 3668_GB...
Страница 2: ...2 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 16: ...16 18 06 08 PVD3668_GB_GVM_June_2018 Consult us for more demanding applications...
Страница 28: ...28 18 06 08 PVD3668_GB_GVM_June_2018 GVM142 050 in Motor operation mode GVM142 050 in Generator operation mode...
Страница 29: ...29 18 06 08 PVD3668_GB_GVM_June_2018 GVM142 075 in Motor operation mode GVM142 075 in Generator operation mode...
Страница 30: ...30 18 06 08 PVD3668_GB_GVM_June_2018 GVM142 100 in Motor operation mode GVM142 100 in Generator operation mode...
Страница 32: ...32 18 06 08 PVD3668_GB_GVM_June_2018 GVM210 100 in Generator operation mode GVM210 150 in Motor operation mode...
Страница 33: ...33 18 06 08 PVD3668_GB_GVM_June_2018 GVM210 150 in Generator operation mode...
Страница 34: ...34 18 06 08 PVD3668_GB_GVM_June_2018 GVM210 200 in Motor operation mode GVM210 200 in Generator operation mode...
Страница 35: ...35 18 06 08 PVD3668_GB_GVM_June_2018 GVM210 300 in Motor operation mode GVM210 300 in Generator operation mode...
Страница 36: ...36 18 06 08 PVD3668_GB_GVM_June_2018 GVM210 400 in Motor operation mode GVM210 400 in Generator operation mode...
Страница 39: ...39 18 06 08 PVD3668_GB_GVM_June_2018 3 3 Dimension drawings 3 3 1 GVM142 outline drawings...
Страница 40: ...40 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 41: ...41 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 42: ...42 18 06 08 PVD3668_GB_GVM_June_2018 3 3 2 GVM210 outline drawings...
Страница 43: ...43 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 44: ...44 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 45: ...45 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 46: ...46 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 47: ...47 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 53: ...53 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 55: ...55 18 06 08 PVD3668_GB_GVM_June_2018...
Страница 60: ...60 18 06 08 PVD3668_GB_GVM_June_2018 With Oil with a 46 cSt viscosity 40 C input at 65 C...