background image

PM-ERV-B/USA 

Maintenance Instructions & Generic Parts List 

 

ERV Series Actuator 

 

 

7

 

Parker Hannifin Corporation 

 

 

Actuator Division 

 

 

Wadsworth, OH  44281 

 

Bumper Accessory 

 
External bumpers are available on these units for safety reasons or as emergency stops.  These bumpers 
are designed as safety stops only and should not be used as end of stroke stops.  Continuously using them 
as end of stroke stops may damage the drive train.  See the diagram below for an exploded view of the 
bumper option. 
 
 

 
 
 

Hall Effect & Reed Switches 

 
Hall Effect and Reed switches are available for sensing the position of the carriage.  This is accomplished by 
detecting the magnet attached to the carriage.  Magnets come as standard on all units.  The switches may 
be attached to either of the side T-slots on the actuator body and are easily adjusted to any position along 
the length.  See the figure below for the mounting bracket hardware needed for the switches. 
 
 
 

 

35

36

37

38

39

Содержание ERV Series

Страница 1: ...Bulletin PM ERV B USA Maintenance Instruction Parts List Revision Date September 2005 Supersedes April 2002 ERV Series Value Line Rodless Linear Actuator...

Страница 2: ...the current product catalog Due to the variety of operating conditions and applications for these products or systems the user through its own analysis and testing is solely responsible for making the...

Страница 3: ...arts information and information on various actuator options Consult the factory or the Product Catalog for additional information ERV Series Linear slides are electromechanical belt driven actuators...

Страница 4: ...onnect the carriage from the shuttle by removing the three carriage bolts 8 6 Roll the carriage off the end of the body extrusion Note the actuator is designed so that the carriage assembly can be rem...

Страница 5: ...Carriage Preload Since this step is Pre loading of a carriage assembly we will only be discussing the off center roller cams The other cams should be properly torqued at this point 20 Use the socket t...

Страница 6: ...rication The wheel and pulley bearings are pre lubricated for the life of the unit No additional lubrication is necessary Actuator Mounting The ERV units should only be mounted down by way of the T sl...

Страница 7: ...as end of stroke stops may damage the drive train See the diagram below for an exploded view of the bumper option Hall Effect Reed Switches Hall Effect and Reed switches are available for sensing the...

Страница 8: ...Low Amp 1 5M Cable With Leads SMRnn 1LC N O Red Low Amp 150mm Cable SMDnn 1LC N C Yellow Low Amp With Quick Dis nn represents place holders for the purpose of ordering pre assembled mounting brackets...

Страница 9: ...er plate 2 ERV56M04 ERV80M04 14 Drive end cap 1 ERV56E02 ERV80E02 15 Belt drive shaft 1 ERV56S02 ERV80S02 16 Pulley 2 ERV56P01 ERV80P01 17 Pulley bearings 4 RA446 RA447 18 Body cover plate 2 ERV56M15...

Страница 10: ...on Of Remedy SELLER S LIABILITY ARISING FROM OR IN ANY WAY CONNECTED WITH THE ITEMS SOLD OR THIS CONTRACT SHALL BE LIMITED EXCLUSIVELY TO REPAIR OR REPLACEMENT OF THE ITEMS SOLD OR REFUND OF THE PURCH...

Страница 11: ...yer or directed to items delivered hereunder for which the designs are specified in whole or part by Buyer or infringements resulting from the modification combination or use in a system of any item s...

Страница 12: ...Parker Hannifin Corporation Actuator Division 135 Quadral Drive Wadsworth Ohio 44281 USA Tel 330 336 3511 Fax 330 334 3335 Web Site http www parker com automation...

Отзывы: