background image

Power Amplifier f. Pressure-/Flow Valves

Series EC106

Installation Manual

IA EC106 UK.INDD RH 02.06

7

Parker Hannifin GmbH & Co. KG

Hydraulic Controls Division

Operating and Diagnostic Elements
(Elevation A)

  z2  0V Supply
  z4  0V Command 1
  z6  0V Supply
  z8  0V Command 2
 z10  0V Supply
 z12  0V Command 3
 z14  0V Command 4

 z18  0V Command 5
 z20  0V Supply
 z22  0V Command 6
 z24  0V Reference output
 z26  0V Reference output
 
 z30  Input 24VDC supply
 z32  Input 24VDC supply

Connector (Elevation B)

  d2  Output solenoid 1
 
  d6  Output solenoid 2
 
 d10  Output solenoid 3

 
 d16  Output solenoid 4
 
 d20  Output solenoid 5

 
 d26  Output solenoid 6
 
 d30  10V reference
 d32  Input 24VDC supply

  b2  Output solenoid 1
  b4  Input command 1 / 0...+10V
  b6  Output solenoid 2
  b8  Input command 2 / 0...+10V
 b10  Output solenoid 3
 b12  Input command 3 / 0...+10V
 b14  Input command 4 / 0...+10V
 b16  Output solenoid 4
 b18  Input command 5 / 0...+10V
 b20  Output solenoid 5
 b22  Input command 6 / 0...+10V
 
 b26  Output solenoid 6
 
 b30  10V reference
 b32  Input 24VDC supply

Notes:

Turn off the electrical power to 
the board whenever removing 
it from the card holder.

Black grip strip

  1  Ramp potentiometer channel 1
  2  Switch p/Q channel 1
  3  Ramp potentiometer channel 2
  4  Switch p/Q channel 2
  5  Ramp potentiometer channel 3
  6  Switch p/Q channel 3
  7  Ramp potentiometer channel 4
  8  Switch p/Q channel 4
  9  Ramp potentiometer channel 5
 10  Switch p/Q channel 5
 11  Ramp potentiometer channel 6
 12  Switch p/Q channel 6

Содержание EC106 Series

Страница 1: ...ssure Flow Valves Installation Manual Series EC106 Parker Hannifin GmbH Co KG Hydraulic Controls Division Gutenbergstr 38 41564 Kaarst Germany Tel 49 181 99 44 43 0 Fax 49 2131 513 230 E mail infohcd parker com Copyright 2002 Parker Hannifin GmbH Co KG ...

Страница 2: ...uselectoruseanyproductorsystem it is important that you analyse all aspects of your application and review the information concerning the product or system in the current product catalogue Due to the variety of operating conditions and applications for these products or systems the user through his own analysis and testing is solely responsible for making the final selection of the products and sys...

Страница 3: ...hannels for the control of up to 6 valves Each channel is equipped with a slide switch for selection of pressure or flow valve operation Ramp function Pulsed low loss amplifier power stages with supportingconstantcurrentcontrolforconstant temperature independent solenoid forces Dither generator with applied frequency to improve static characteristics Ordering Code Design 2 channels 4 channels 6 chan...

Страница 4: ...ressure Flow Valves Series EC106 Installation Manual 4 Parker Hannifin GmbH Co KG Hydraulic Controls Division Block Diagram 2 Channel Option EMC EN 50081 2 EN 55011 EN 50082 2 ENV 50140 EN 61000 4 4 ENV 50204 EN 61000 4 5 EN 61000 4 2 EN 61000 4 6 ...

Страница 5: ...Power Amplifier f Pressure Flow Valves Series EC106 Installation Manual IA EC106 UK INDD RH 02 06 5 Parker Hannifin GmbH Co KG Hydraulic Controls Division Block Diagram 4 Channel Option ...

Страница 6: ...IA EC106 UK INDD RH 02 06 Power Amplifier f Pressure Flow Valves Series EC106 Installation Manual 6 Parker Hannifin GmbH Co KG Hydraulic Controls Division Block Diagram 6 Channel Option ...

Страница 7: ...put 10V reference d32 Input 24VDC supply b2 Output solenoid 1 b4 Input command 1 0 10V b6 Output solenoid 2 b8 Input command 2 0 10V b10 Output solenoid 3 b12 Input command 3 0 10V b14 Input command 4 0 10V b16 Output solenoid 4 b18 Input command 5 0 10V b20 Output solenoid 5 b22 Input command 6 0 10V b26 Output solenoid 6 b30 Output 10V reference b32 Input 24VDC supply Notes Turn off the electric...

Страница 8: ...wer supply and solenoids AWG 15 other connections AWG 20 The capacity should not exceed a value of approx 130 pF m wire wire The maximum cable lengthis50m Nopowercurrentlinesmaybeplaced within the wired shielded cables to the electronic module The cable shield has to be connected to groundatbothends seealsochapter Grounding Please be aware of ground loops Installation The module has to be mounted ...

Отзывы: