background image

Power Amplifier f. Pressure-/Flow Valves

Series EC106

Installation Manual

IA EC106 UK.INDD RH 02.06

3

Parker Hannifin GmbH & Co. KG

Hydraulic Controls Division

Design

Series

Module Type 

Amplifier, 

switchable, 

pressure-/flow 

valves, Ramps

Electronic Module

for Pressure-/ Flow 

Valves

DSA, DWE, DWU

RE*W, TDA*LAF, 

TEA*LAF

Number of 

Channels

Electronic  module  for  the  control  of  proportional 
pressure or flow valves. The pressure-/ flow values 
are given by externally supplied command signals 
and internal ramp potentiometers.

Features

•  Processing and amplification of externally sup-

plied positive commands into output signals for 
the control solenoid.

•  Up to 6 independent channels for the control of 

up to 6 valves.

•  Each channel is equipped with a slide switch for 

selection of pressure or flow valve operation.

•  Ramp function
•  Pulsed  low  loss  amplifier  power  stages  with 

supporting constant current control for constant, 
temperature independent solenoid forces.

•  Dither  generator  with  applied  frequency  to 

improve static characteristics.

Ordering Code

Design

2 channels

4 channels

6 channels

Supply voltage

[V]

24 ±10%

Power consumption max.

[VA]

70

125

190

Command voltage

[VDC]

0...+10

Reference output

[VDC]

10 ±5% / max. 100mA

Solenoid output current, max.

[A]

2 x 1.3

4 x 1.3

6 x 1.3

Ramps

[s]

0.01...10

Ambient temperature

[°C]

0...+70

Connection

48pole male connector, DIN 41612F

Cable connection

Supply conne valve: AWG15; command inputs AWG20

Fuse DIN 41571

4A medium lag

6.3A medium lag

10A medium lag

Characteristics

EC

106

Code

Quantity

02

2

04

4

06

6

Содержание EC106 Series

Страница 1: ...ssure Flow Valves Installation Manual Series EC106 Parker Hannifin GmbH Co KG Hydraulic Controls Division Gutenbergstr 38 41564 Kaarst Germany Tel 49 181 99 44 43 0 Fax 49 2131 513 230 E mail infohcd parker com Copyright 2002 Parker Hannifin GmbH Co KG ...

Страница 2: ...uselectoruseanyproductorsystem it is important that you analyse all aspects of your application and review the information concerning the product or system in the current product catalogue Due to the variety of operating conditions and applications for these products or systems the user through his own analysis and testing is solely responsible for making the final selection of the products and sys...

Страница 3: ...hannels for the control of up to 6 valves Each channel is equipped with a slide switch for selection of pressure or flow valve operation Ramp function Pulsed low loss amplifier power stages with supportingconstantcurrentcontrolforconstant temperature independent solenoid forces Dither generator with applied frequency to improve static characteristics Ordering Code Design 2 channels 4 channels 6 chan...

Страница 4: ...ressure Flow Valves Series EC106 Installation Manual 4 Parker Hannifin GmbH Co KG Hydraulic Controls Division Block Diagram 2 Channel Option EMC EN 50081 2 EN 55011 EN 50082 2 ENV 50140 EN 61000 4 4 ENV 50204 EN 61000 4 5 EN 61000 4 2 EN 61000 4 6 ...

Страница 5: ...Power Amplifier f Pressure Flow Valves Series EC106 Installation Manual IA EC106 UK INDD RH 02 06 5 Parker Hannifin GmbH Co KG Hydraulic Controls Division Block Diagram 4 Channel Option ...

Страница 6: ...IA EC106 UK INDD RH 02 06 Power Amplifier f Pressure Flow Valves Series EC106 Installation Manual 6 Parker Hannifin GmbH Co KG Hydraulic Controls Division Block Diagram 6 Channel Option ...

Страница 7: ...put 10V reference d32 Input 24VDC supply b2 Output solenoid 1 b4 Input command 1 0 10V b6 Output solenoid 2 b8 Input command 2 0 10V b10 Output solenoid 3 b12 Input command 3 0 10V b14 Input command 4 0 10V b16 Output solenoid 4 b18 Input command 5 0 10V b20 Output solenoid 5 b22 Input command 6 0 10V b26 Output solenoid 6 b30 Output 10V reference b32 Input 24VDC supply Notes Turn off the electric...

Страница 8: ...wer supply and solenoids AWG 15 other connections AWG 20 The capacity should not exceed a value of approx 130 pF m wire wire The maximum cable lengthis50m Nopowercurrentlinesmaybeplaced within the wired shielded cables to the electronic module The cable shield has to be connected to groundatbothends seealsochapter Grounding Please be aware of ground loops Installation The module has to be mounted ...

Отзывы: