29
DB Series Nitrogen Generator
DB5-20 Model
5.2 Configuring Static IP Address
A static IP address can be configured by accessing the low-level system menus of the PLC.
1. From main screen, press
OK
and
ESC
button simultaneously to exit to the PLC’s system menus.
2. Switch from RUN mode to PROGRAM mode
a. Select “Mode Switch” and hit
OK
b. Select the
UP
or
DOWN
key to change to “PROG”
c. Hit
OK
to select
3. Go to ADVANCED > ENET CFG > IP Address Settings
a. Use
UP
key to go to “Advanced Settings” and select
OK
b. Use
UP
key to go to “IP Address Settings” and select
OK
c. Use
Arrow keys
to set the following:
i. Change ENET Mode to Static
ii. Set IP Address
iii. Set Subnet Mask
iv. Set Gateway Address if required.
d. Select “Save Settings”
**IMPORTANT! Do not skip this step**
4. Verify Settings
a. Use
UP
key to go to “Advanced Settings” and select
OK
b. Use
UP
key to go to “ENET CFG” and select
OK
c. Select “ENET Status” to verify the new settings
5. Switch back to RUN mode
**IMPORTANT! Do not skip this step**
6. Turn power off then back on using power switch located below on bottom of control box
5.3 RS232 or RS485 Communications
If the dryer must be connected to an RS485 network or RS232 port, use a Modbus Gateway device,
such as Parker’s part number SW2400-MOD (sold separately).
Содержание DB Series
Страница 1: ...DB Series Nitrogen Generator Owner s Manual Models DB5 20...
Страница 31: ...31 DB Series Nitrogen Generator DB5 20 Model 5 Select RTU Master Mode 6 Configure Network as follows...
Страница 41: ...41 DB Series Nitrogen Generator DB5 20 Model DB 5 10 PPM PCT FD 9 Flow Schematics...
Страница 42: ...42 DB Series Nitrogen Generator DB5 20 Model DB 15 20 PPM PCT FD...
Страница 55: ...55 DB Series Nitrogen Generator DB5 20 Model Notes...
Страница 56: ...56 DB Series Nitrogen Generator DB5 20 Model Notes...
Страница 57: ...57 DB Series Nitrogen Generator DB5 20 Model Notes...