Parker Compax3M Series Скачать руководство пользователя страница 4

 

Notes on the Documents Supplied

 

Your PC is connected to the PSUP (mains module) connector X3 via an USB cable 
(SSK33/03). 
Start the Compax3 servo manager and make the setting for the assigned interface 
in the menu"

Options: Communication settings RS232/RS485...

". 

The interface is marked as "USB Serial Port (COMx)" in the windows device 
manager. The no. of the COM port "x" may vary. You can find it in the PC under 
system control, system, hardware, device manager, connections. 

In the menu tree under device selection you can read the device type of the 
connected device (Online Device Identification) or select a device type (Device 
Selection Wizard). 

Then you can double click on "Configuration" to start the configuration wizard. The 
wizard will lead you through all input windows of the configuration. 

Content 

1. Notes on the Documents Supplied ........................................................ 3

1.1

 

C3 ServoManager ..................................................................................... 3

 

2. Introduction ............................................................................................. 5

2.1

 

Device assignment .................................................................................. 5

 

2.2

 

Scope of delivery ..................................................................................... 5

 

2.3

 

Type specification plate .......................................................................... 5

 

2.4

 

Packaging, transport, storage ................................................................ 7

 

2.5

 

Safety instructions ................................................................................... 8

 

2.5.1.

 

General hazards ................................................................................................. 8

 

2.5.2.

 

Working safely / qualification ........................................................................... 8

 

2.5.3.

 

Special dangers ................................................................................................. 8

 

2.6

 

Warranty conditions ................................................................................ 9

 

2.7

 

Conditions of utilization .......................................................................... 9

 

2.7.1.

 

Conditions of utilization for CE-conform operation ....................................... 9

 

2.7.2.

 

Conditions of utilization for UL approval Compax3M .................................. 11

 

2.7.3.

 

Conditions of utilization for UL approval PSUP ........................................... 12

 

2.7.4.

 

Current on the mains PE (leakage current) ................................................... 13

 

2.7.5.

 

Supply networks .............................................................................................. 13

 

2.8

 

EC declaration of conformity Compax3M ............................................ 14

 

2.9

 

EC declaration of conformity PSUP ..................................................... 15

 

3. Device description ................................................................................ 16

3.1

 

Installation instructions Compax3M .................................................... 16

 

3.2

 

Mounting and dimensions ..................................................................... 17

 

3.2.1.

 

Mounting and dimensions PSUP10/C3M050D6, C3M100D6, 

C3M150D6 ......................................................................................................... 17

 

3.2.2.

 

Mounting and dimensions PSUP20/PSUP30/C3M300D6 ............................. 18

 

4. Technical Data ....................................................................................... 19

Connection 

PC-PSUP 

Device Selection 

Configuration 

192-

120148N13 2019-06

 

Multi-axis devices

 

Содержание Compax3M Series

Страница 1: ...ti axis devices 192 120148N13 2019 06 Release as from R09 63 192 120148N13 2019 06 We reserve the right to make technical changes The data correspond to the current status at the time of printing DOC...

Страница 2: ...echanical Drives Division EME Robert Bosch Strasse 22 77656 Offenburg Germany Tel 49 0781 509 0 Fax 49 0781 509 98176 Internet www parker com eme http www parker com eme E mail sales automation parker...

Страница 3: ...online help files Please note that the help files are associated with defined device and software versions Status of the Manuals Help and PDFs are updated simultaneously In case of doubt the HTML help...

Страница 4: ...ts Supplied 3 1 1 C3 ServoManager 3 2 Introduction 5 2 1 Device assignment 5 2 2 Scope of delivery 5 2 3 Type specification plate 5 2 4 Packaging transport storage 7 2 5 Safety instructions 8 2 5 1 Ge...

Страница 5: ...s module PSUP20D6 mains module PSUP30D6 mains module 2 2 Scope of delivery Device accessories Device accessories for Compax3M Cable clamps in different sizes for large area shielding of the motor cabl...

Страница 6: ...supply V2 Mains supply voltage 2 230VAC 240VAC 4 400VAC 480VAC 3 Unique number of the particular device 4 Nominal supply voltage Power Input Input supply data Power Output Output data 5 Designation o...

Страница 7: ...environmental laws The following table states the materials suitable for recycling and the materials which have to be disposed of separately Material suitable for recycling Disposal Metal yes no Plas...

Страница 8: ...rvices who have read and will observe the safety instructions who have read and observe the manual or help or the sections pertinent to the work to be carried out This applies to all work relating to...

Страница 9: ...mounting methods Note on exchange of options Device options must be exchanged in the factory to ensure hardware and software compatibility When installing the device make sure the heat dissipators of...

Страница 10: ...hed with the device The shield of the cable must also be connected with the motor housing The fixing via plug or screw in the terminal box depends on the motor type 80m Corresponding to the specificat...

Страница 11: ...in the accessories chapter they feature a temperature rating of at least 60 C Maximum Surrounding Air Temperature 40 C Control voltage supply 24VDC only permissible with class 2 power supply Compax3M...

Страница 12: ...the cables described in the accessories chapter they feature a temperature rating of at least 60 C Maximum Surrounding Air Temperature 40 C Control voltage supply 24VDC only permissible with class 2 p...

Страница 13: ...on the following factors Length and properties of the motor cable Switching frequency Operation with or without external mains filter Motor cable with or without shield network Motor housing groundin...

Страница 14: ...Introduction 2 8 EC declaration of conformity Compax3M 14 192 120148N13 2019 06 Multi axis devices...

Страница 15: ...Parker EME EC declaration of conformity PSUP 2 9 EC declaration of conformity PSUP 192 120148N13 2019 06 15...

Страница 16: ...screw type e g 5 9Nm for M5 screw DIN 912 8 8 Connection of the internal supply voltage The Compax3M axis controllers are connected to the supply voltages via the rail modules Details Deblocking the...

Страница 17: ...to other temperature influences than that of the devices mounted on this very plate The devices must be mounted vertically on a level surface Make sure that all devices are sufficiently fixed 3 2 1 Mo...

Страница 18: ...g and dimensions PSUP20 PSUP30 C3M300D6 Information on PSUP20 PSUP30 C3M300D6 Mounting 4 socket head screws M5 100mm 360mm 263mm 96mm 400mm 90 50 5mm 50 5mm 101mm Tolerances DIN ISO 2768 f 18 192 1201...

Страница 19: ...mum fuse rating per device 2 special purpose fuses in line are required Cable protection measure MCB K characteristic with a rating of 50A 4xxVAC depending on the input voltage Recommendation ABB S203...

Страница 20: ...Technical Data 20 192 120148N13 2019 06 Multi axis devices...

Отзывы: