Introduction
Multi-axis devices
16
192-120148N5 June 2011
2.7
Conditions of utilization
Conditions of utilization for CE-conform operation
In this chapter you can read about:
........................................................... 16
nditions of utilization for UL certification Compax3M
.................................................... 19
Current on the mains PE (leakage current) ...................................................................... 20
Supply networks .............................................................................................................. 21
2.7.1.
Conditions of utilization for CE-conform operation
Conditions of utilization mains filter
In this chapter you can read about:
................................................................................. 16
Conditions of utilization for cables / motor filter ............................................................... 17
Additional conditions of utilization.................................................................................... 17
- Industry and trade -
The EC guidelines for electromagnetic compatibility 2004/108/EC and for electrical
operating devices for utilization within certain voltage limits 2006/95/EC are fulfilled
when the following boundary conditions are observed:
Operation of the devices only in the condition in which they were delivered,
i.e. with all housing panels.
In order to ensure contact protection, all mating plugs must be present on the
device connections even if they are not wired.
Please respect the specifications of the manual, especially the technical
characteristics (mains connection, circuit breakers, output data, ambient
conditions,...).
2.7.1.1
Conditions of utilization mains filter
A mains filter is required in the mains input line if the motor cable exceeds a certain
length. Filtering can be provided centrally at the system mains input or separately
for each axis system.
The following mains filters are available for independent utilization:
Use of the devices in a commercial and residential area (limit value class in
accordance with EN 61800-3)
The following mains filters are available for independent utilization:
Use of the devices in the industrial area (limit values class C3 in accordance
with EN 61800-3)
Device: PSU
Limit value
class
Reference: Axis system
with motor cable
Mains filter
Order No.:
P10
C3
< 6 x 10 m
NFI03/01
P10
C3
< 6 x 50 m
NFI03/02
P20
C3
< 6 x 50 m
NFI03/03
P30
C3
< 6 x 50 m
NFI03/03
unshielded:
Connection length: Connection between mains filter and device:
< 0.5 m
shielded
< 5 (fully shielded on ground - e.g. ground of control cabinet)
Mains filter: