CM0504 User Guide
13
4.2.2.
Power control digital input connections
If•the•active•high•digital•input•is•configured•to•wake•up•the•module:
•
•
The•power•control•digital•input•is•usually•connected•to•the•vehicle•ignition,•but•it•can•be•connected•
to•any•power•source•in•a•system.
•
•
To•protect•the•harness•that•connects•the•CM0504•to•the•ignition,•place•a•fuse•of•200•mA•or•higher•in•
the•circuit•that•feeds•the•CM0504.
•
•
When•battery•power•(VBATT)•is•connected,•and•the•power•control•digital•input•is•inactive,•the•
CM0504•will•go•into•sleep•mode.
•
•
The•CM0504•has•‘Wake•on•CAN’•capability.•Even•when•it•is•not•configured•for•wake•on•CAN,•the•bus•
must•be•completely•silent•in•order•for•the•CM0504•to•stay•in•low•power•sleep•mode.•Until•the•correct•
wakeup•conditions•are•sensed,•the•CM0504•will•appear•“off”•(outputs•off•and•no•CAN•tx)•but•there•is•
no•way•to•keep•its•power•supply•off•if•there•is•CAN•activity•on•the•bus.•
If•your•CM0504•must•always•be•powered,•the•power•control•digital•input•does•not•need•to•be•used.•The•
CM0504•can•be•configured•to•always•be•powered•using•the•CM0504•Configuration•Tool•software.
The•following•diagram•shows•a•typical•power•control•digital•input•connection:
•
Internal to product
Power Control Input
Power
Control
Pull-Down
Resistor
Battery
Application Switch
Figure 4.3. Power control digital input installation connections
4.3. INPUT2 and INPUT3, alternate functions
The•alternate•functions•for•inputs•INPUT2•-•INPUT3•is•as•digital•(active-low)•inputs•and•as•frequency•
(type•1•&•type•2)•inputs.
Содержание CM0504
Страница 1: ...CM0504 User Guide Controller Module Effective April 2019 Supersedes UG CM0504 1038000 201808 007...
Страница 10: ...CM0504 User Guide 3 Symbol Meaning Pull up resistor Battery Fuse Resistor Ground Chassis ground...
Страница 16: ...CM0504 User Guide 9 J4 Connector Pinout Pin I O Name Function 1 VBATT Positive battery terminal HS output power...
Страница 52: ...CM0504 User Guide 45 Figure 11 3 Install S W button Figure 11 4 Software file dialog box...