CM0504 User Guide
12
Internal to product
Sensor Power
Resistive Sensor
Pull-up
Resistor
Active Sensor
Analog Input
Analog Input
Figure 4.2. Analog input ground shift connection for sensors that have dedicated ground wires
4.2. Power control digital input
The•CM0504•has•1•active-high•power•control•digital•input•that•is•used•for•waking•up•(turning•on)•the•
product•(
INPUT1
).
This•type•of•input•has•a•pull-down•resistor•option•only.•When•the•input•is•active•it•turns•on•the•power•
supply•pass•transistor•to•power•up•the•unit.•The•input•is•sensed•directly•by•the•microprocessor.
4.2.1.
Power control input, circuit characteristics
The•following•table•provides•specifications•for•the•CM0504•power•control•digital•input:
Power control digital input characteristics
Item
MIN
NOM
MAX
UNIT
Input voltage range
0
32
V
Over-voltage
36
V
Pull-down resistance
21.2
kΩ
Capacitance at pin
1000
pF
Input Power Up Threshold
2.5
4.3
V
•
Note:
The•power•control•digital•input•voltage•must•be•greater•than•4.3•V•before•it•is•considered•an•active•
high•input.
The•power•control•digital•input•wakes•up•the•CM0504•when•switched•high•to•a•voltage•of•4.3•V•or•greater.•
The•CM0504•will•shut•off•when•an•open•circuit•condition•occurs•on•the•power•control•digital•input,•
unless•it•is•configured•to•‘Wake•on•CAN’.
Содержание CM0504
Страница 1: ...CM0504 User Guide Controller Module Effective April 2019 Supersedes UG CM0504 1038000 201808 007...
Страница 10: ...CM0504 User Guide 3 Symbol Meaning Pull up resistor Battery Fuse Resistor Ground Chassis ground...
Страница 16: ...CM0504 User Guide 9 J4 Connector Pinout Pin I O Name Function 1 VBATT Positive battery terminal HS output power...
Страница 52: ...CM0504 User Guide 45 Figure 11 3 Install S W button Figure 11 4 Software file dialog box...