Aries Controller
ACR-View Configuration: Limits and Home
Parker Mechanics
Aries Controller with Parker Mechanics
Parker Mechanics are offered with a wide array of choices for limits and home
sensors. Any of these combinations can be used with the Aries Controller. The
Aries Controller can utilize either NPN (sinking) or PNP (sourcing) style sensors
ranging from 5-24 VDC input levels.
• Aries controller includes 7 general purpose inputs, any of which can be
configured for limits and home function.
• Limits and home must be selected on 3 consecutive inputs, ordered as
positive, negative and home
• Normally Open (NO) or Normally Closed (NC) activation level can be
configured for each individual input.
• Input voltage must be supplied externally
• Inputs are accessed via the controller 25-pin connector. The VM25 breakout
module offers a convenient way to wire the inputs.