3
Parker Autoclave Engineers
Instrumentation Products Division
Erie, PA USA
www.autoclave.com | Cat. 02-9221ME
Section 1.0
Safety and Operating Environment
1.1
This machine is designed to be operated under clean
and dry conditions. Operating environment temperatures
should not be below 32°F (0°C) or greater than 100°F
(38°C).
Note:
Operations below 60°F (15.6°C) will require the
heater option for the cutting oil reservoir.
1.2 Proper circulation of the cutting oil throughout the ma-
chine is critical and depending on the ambient tempera-
ture it may be necessary to allow time for the oil to warm
up enough to circulate freely. Do not perform coning or
threading operations until oil flows from the tubes.
1.3
To avoid electric hazards and damage to the machine,
the unit should not be exposed to rain, snow or other
sources of moisture.
1.4
Only trained personnel familiar with these operating
procedures should operate this machine.
1.5
This machine contains exposed moving parts.
Operat-
ing personnel should use caution not to place hands and
fingers into moving parts such as the die head and the
cutter blades. Operating personnel should also use cau-
tion and not wear loose clothing and/or jewelry that may
become tangled in the machinery. The belt guard and
control box covers must be in place at all times and are
only to be removed by qualified service personnel with
the power cord disconnected.
1.6
Operating personnel shall wear eye protection at all times
while operating this machine.
1.7
When changing tooling or servicing the machine, unplug
the power cord. In the event that either the motor or the
pump become stalled, unplug the power cord immedi-
ately to avoid the hazard of electrical fire or damage to
the components.
1.8
Prevent feedwheel from rotating or moving into the cutter
assembly when not in use by securing the feedwheel with
the chained hook.
1.9
Applies to Model AEGCTM-2E-CE only: The total power
consumption for the unit is 450 watts. The locked rotor
current rating for this unit is 29.5 amps. All electrical
components are wired and designed to comply with
EN60204-1.
1.10 Applies to Model AEGCTM-2E-CE only: AEGCTM-2E-CE
Coning and Threading machines equipped with an oil
heater utilize an over-current protected heating element
rated for 8.9 amps. Attempts to modify, override or
bypass this device will void the warranty and may result
in an electrical fire or damage to the components.
Section 2.0
Initial Setup of Coning and Threading Machine
2.1
Install four caster wheels using included hardware.
Note:
All caster wheels have locks to prevent movement
of machine during operation.
2.2 Remove plastic restraining straps securing the yoke
assemblies.
Figure 1
Front and rear view of Coning and Threading Machine
Содержание AEGCTM-2
Страница 14: ...14 Parker Autoclave Engineers Instrumentation Products Division Erie PA USA www autoclave com Cat 02 9221ME ...
Страница 15: ...15 Parker Autoclave Engineers Instrumentation Products Division Erie PA USA www autoclave com Cat 02 9221ME ...
Страница 16: ...16 Parker Autoclave Engineers Instrumentation Products Division Erie PA USA www autoclave com Cat 02 9221ME ...
Страница 17: ...17 Parker Autoclave Engineers Instrumentation Products Division Erie PA USA www autoclave com Cat 02 9221ME ...
Страница 18: ...18 Parker Autoclave Engineers Instrumentation Products Division Erie PA USA www autoclave com Cat 02 9221ME ...
Страница 19: ...19 Parker Autoclave Engineers Instrumentation Products Division Erie PA USA www autoclave com Cat 02 9221ME ...
Страница 21: ...21 Parker Autoclave Engineers Instrumentation Products Division Erie PA USA www autoclave com Cat 02 9221ME ...
Страница 22: ...22 Parker Autoclave Engineers Instrumentation Products Division Erie PA USA www autoclave com Cat 02 9221ME ...
Страница 23: ...23 Parker Autoclave Engineers Instrumentation Products Division Erie PA USA www autoclave com Cat 02 9221ME ...