The Keypad
5-1
650V AC Drive
Chapter 5
T
HE
K
EYPAD
The 6511 Keypad (Man-Machine Interface, MMI)
provides for local control of the drive, monitoring,
and complete access for application programming
a connection to a pc is required along with the
drive software tool.
The 650V can be fitted with either a Standard or
Remote Keypad. Both Keypads fit on the front of
the drive, but the Remote Keypad (with its extra
connector) can also be remote-mounted up to 3
metres away using a connecting lead: refer to
Chapter 3: “Installing the Drive” – Fitting the
Remote Keypad.
To remove a Keypad, simply pull it away from the
drive. To refit it, push it back into place.
The product rating label identifies the Drive/Keypad type: refer to Chapter 9: “Technical
Specifications” – Understanding the Product Code.
The Power-Up Condition
On initial power-up, direct from the factory, the drive is in Local Control and the MMI will
display the Local Setpoint,
.
All parameters will be at factory default settings. Any changes to these conditions are
automatically saved. The drive will initialise on subsequent power-ups with the previously saved
settings and control mode, Local or Remote Control.
Controlling the Drive using the Keypad
Control Key Definitions
Key
Operation
Description
Escape
Navigation
– Displays the previous level’s menu
Parameter
– Returns to the parameter list
Trip Display
– Removes Trip or Error message from display
allowing investigation of parameters
Menu
Navigation
– Displays the next menu level, or the first
parameter of the current Menu
Parameter
– Moves cursor to the left when the parameter is
adjustable
Increment
Navigation
– Move upwards through the menu system
Parameter
– Increase value of the displayed parameter
Local Mode
– Increase value of the local setpoint
Decrement
Navigation
– Move down through the menu system
Parameter
– Decrease value of the displayed parameter
Local Mode
– Decrease value of the local setpoint
Run
Local Mode
– Run the drive
Trip Reset
– Resets trip condition allowing drive to resume
operation
Stop
Local Mode
– Stops the drive. Trip Reset in all modes
Navigation –
Press and hold to toggle between Local and
Remote Control modes (refer to page 5-5)
Trip Reset
– Resets trip condition allowing drive to resume
operation
Programming Keys
Local
Key
Control
Local
Key
Control