DOC-0017-07-EN: AC20 Series - EtherCAT Option
DOC-0017-07-EN-A
27.03.2023
19 (58
)
Set process data using AC20 input and output mapping tables
These tables are two parameter arrays in which AC20 parameter numbers may be added. The parameter
2566 MASTERMAPPING
must be set to
FALSE.
Read Mapping:
The read process data represents cyclic data sent from the PLC to the AC20, this is mapped into the table
Option Comms
Input Mapping
. Only writable AC20 parameters that are not configuration parameters may
be added to the read process data.
Keypad Menu Path
DSE Lite Function Block Webserver
Write Mapping:
The write process data represents cyclic data sent from the AC20 to the PLC, this is mapped into the table
Option Comms Output Mapping.
Keypad Menu Path
DSE Lite Function Block Webserver
Note: String-type parameters cannot be mapped.
Engineer
Communications
Option Comms
Input Mapping[ ]
Engineer
Communications
Option Comms
Output Mapping[ ]