Easy Start Guide

7. How to operate the Inverter from the keypad

Page 7

This guide has been produced by The Inverter Drive Supermarket Ltd.
All content, including but not limited to graphics, text and procedures copyright

The Inverter

Drive Supermarket and must not be reproduced or altered without prior written permission.

©

The green key will start the motor. The display will reset to 0.00 and
increase as the motor accelerates. The time taken for the motor to
accelerate to the desired speed (in seconds) is proportional to
parameter F114. The “RUN” indicator will illuminate to indicate that the
motor is running. To change the speed whilst the motor is running, use
the up and down keys.

7.3 Press the green “RUN” key to start the motor.

Note: When running, the “M” key can be used to cycle through
other values such as motor rpm, current (A) and voltage (U).

Parker AC10 Series Inverter (to 22kW)

7.1 Select the speed reference.

Press the “M” key repeatedly until the speed reference is shown - the
“Frq” lamp will illuminate. The default is 50.00 (Hz). All digits will
flash except the currently-selected digit. It is the digit that is not
flashing that can be changed.

Note: Once the value is changed it is saved automatically. There
is no need to “save” the value.

Use the “0" (stop) key to move between digits. Use the up and down
arrow keys to change the value as required.

7.2 Set the desired speed.

The “E” key can be used to return the selection to the right-
most digit.

7.4 Press the red “Stop” key to stop the motor.

The red key will stop the motor. The time taken (in seconds) to stop the
motor is proportional to parameter F115.

Once the motor is stopped, the run lamp will not be illuminated and the
display will return to the flashing setpoint shown in 7.2 (above).

Содержание AC10 series

Страница 1: ...a safety device All safety considerations including but not limited to Emergency Stop provision should be assessed separately and are outside the scope of this guide Parker AC10 Frequency Inverter to...

Страница 2: ...nd configure a Potentiometer for remote speed control Contents Parameters Overview Parameters to set before use How to connect and configure a Run Stop switch with Forward Reverse selection Power and...

Страница 3: ...tor phases determines the initial direction the motor turns Notes Important Use screened or armoured cable between the Inverter and Motor and ensure it is grounded as shown The supply must match the I...

Страница 4: ...is not important They should be connected to the terminals marked L1 R L2 S and L3 T as shown In some cases these terminals may be marked L1 L2 and L3 only Notes The order of the three motor phases d...

Страница 5: ...hanging from Delta to allow the motor to be changed back in future For safety purposes Star shown opposite is the default configuration for small motors usually to 3kW and is sometimes known as two at...

Страница 6: ...power down 0 F228 Application Selection Defaults below are based on F228 0 Default is will suit most applications 5 different application Macros available 0 F801 Rated Motor Power kW Rated kW of the...

Страница 7: ...roup mode the DGT digit lamp is not illuminated 6 2 Select the required parameter group Use the up and down keys to select parameter group F800 6 3 Select the required parameter Press the 0 stop key t...

Страница 8: ...used to cycle through other values such as motor rpm current A and voltage U Parker AC10 Series Inverter to 22kW 7 1 Select the speed reference Press the M key repeatedly until the speed reference is...

Страница 9: ...Motor Power kW Rated kW of the motor Set to match the motor nameplate eg 2 2kW 2200 F802 Rated Motor Voltage V Rated Voltage of the motor Set to match the motor nameplate eg V 230 F803 Rated Motor Cu...

Страница 10: ...rated from 2kOhm to 5kOhm can be used eg 4 7kOhm The default output frequency at 0V is the minimum frequency of the Inverter To change this edit Parameter F112 The default output frequency at 10V is...

Страница 11: ...on opposite When a connection is made between terminals 24V and DI3 the motor will run forward When terminals 24V and DI4 are connected the motor will run in reverse The selected direction of rotation...

Страница 12: ...15 set to to select Run Fwd 15 F319 DI4 terminal function setting Default is 16 set to to select Run Rev 16 11 1 Parameters to change for remote Run Stop Two suitable 2 position NO Normally Open swit...

Страница 13: ...rse Select Open Forward Closed Reverse 16 12 1 Parameters to change for remote 3 wire control Note that the Forward Reverse switch can be used to set the direction when the motor is stopped or running...

Страница 14: ...or manual issued by the manufacturer for details 13 2 Connecting the Resistor The braking resistor may get hot during operation Ensure that it is suitably mounted so any heat generated will not affec...

Страница 15: ...0 F800 etc Use the up and down keys to select parameter group F100 14 2 Select parameter group 1 Note In parameter group mode the DGT digit lamp is not illuminated Use the up and down keys to select p...

Отзывы: