background image

Refrigerating Specialties Division

8

M M

IN C H

M M

IN C H

M M

IN C H

M M

IN C H

M M

IN C H

M M

IN C H

A

(ALL)

164

6.2

203

8.0

251

9.9

252

9.9

311

12.2

359

14.1

B

(ALL)

244

9.6

248

9.8

287

11.3

302

11.9

324

12.8

361

14.2

C

(ALL)

378

14.9

396

15.6

450

17.7

470

18.5

582

23.0

665

26.2

FPT

3/4

229

9.0

1-1/4

269

10.6

1-1/2

318

12.5

2-1/2

343

13.5

3

401

15.8

4

462

18.2

PIPE

1

229

9.0

1-1'

2

269

10.6

2

318

12.5

SIZE

1-1/4

229

9.0

SW

3/4

229

9.0

1-1/4

269

10.6

1-1/2

318

12.5

2-1/2

343

13.5

3

401

15.8

4

462

18.2

PIPE

1

229

9.0

1-1/2

269

10.6

2

318

12.5

SIZE

1-1/4

229

9.0

W N

3/4

267

10.5

1-1/4

312

12.3

1-1/2

376

14.8

2-1/2

414

16.3

3

490

19.3

4

584

23.0

PIPE

1

274

10.8

1-1/2

318

12.5

2

384

15.1

SIZE

1-1/4

274

10.8

O D S

1-1/8

300

11.8

1-3/8

338

13.3

1-5/8

427

16.8

2-5/8

445

17.5

3-1/8

508

20.0

4-1/8

625

24.6

TU BE

1-3/8

297

11.7

1-5/8

339

13.8

2-1/8

417

16.4

3-1/8

480

18.9

3-5/8

554

21.8

SIZE

1-5/8

313

12.3

2-1/8

384

15.1

2-5/8

442

17.4

H

(ALL)

117

4.6

117

4.6

140

5.5

159

6.2

176

7.0

222

8.8

J

(ALL)

98

3.9

178

7.0

251

9.9

314

12.4

314

12.4

363

14.3

D

E

F

G

2-1/2

3

4

D IM EN SIO N

SIZE

3/4 & 1

1-1/4

1-5/8 & 2

A4AT A4AO T VALV E D IM EN SIO N TA BLE

PO R T

20 & 25 M M

32 M M

40 & 50 M M

65 M M

75 M M

100 M M

Parker Hannifin Corporation • Refrigerating Specialties Division
2445 South 25th Avenue • Broadview, IL 60155-3891USA
Telephone (708) 681-6300 • Fax (708) 681-6306

Содержание A4AT-DN

Страница 1: ...agm Manual Opening Stem Complies with Pressure Equipment Directive 97 23 EC Description These compact heavy duty pilot operated regula tors are suitable for Ammonia R22 R134a R404a R707 and other comm...

Страница 2: ...perature setting A4AOT REVERSE ACTING TEMPERATURE REGULATOR The A4AOT Regulator modulates flow in response to the temperature variations sensed by its thermal bulb A special temperature pilot replaces...

Страница 3: ...such that the regula tor can not be easily damaged by material handling equipment When it is necessary to insulate the regulator and companion strainer the insulation should be installed to provide ac...

Страница 4: ...N GGG 40 3 42 4 1 61 L ADAPTER 2 A4A DN DUCTILE IRON GGG 40 3 COVER BOTTOM A4A S4A 1 5 8 to 2 1 2 DUCTILE IRON GGG 40 3 BONNET A4W DUCTILE IRON GGG 40 3 COMPONENT DESCRIPTION MATERIAL Kv VOLUME BODY 2...

Страница 5: ...nce moisture can condense on parts and cause rapid rusting When replacing gaskets they should be oiled very lightly with refrigerant oil before assembly Items which require several bolts to fasten mus...

Страница 6: ...er device is opened or removed Flanges with ODS connections are not suitable for ammonia service Warranty All Refrigerating Specialties products are warranted against defects in workmanship and materi...

Страница 7: ...ng 35 Dirt Wiper Retainer 36 Dirt Wiper 37 Seal Bottom Cap 38 Bottom Cap 39 Screw Bottom Cap 40 Packing Washer 41 Packing Ring 42 Stuffing Box Nut 43 Gasket Seal Cap 44 Seal Cap 45 Gasket Flange 46 Bo...

Страница 8: ...5 1 1 4 312 12 3 1 1 2 376 14 8 2 1 2 414 16 3 3 490 19 3 4 584 23 0 PI PE 1 274 10 8 1 1 2 318 12 5 2 384 15 1 SI ZE 1 1 4 274 10 8 O DS 1 1 8 300 11 8 1 3 8 338 13 3 1 5 8 427 16 8 2 5 8 445 17 5 3...

Отзывы: